12.14 JTAG Support
The TECT3 supports the IEEE Boundary Scan Specification as described in the
IEEE 1149.1 standards. The Test Access Port (TAP) consists of the five
standard pins, TRSTB, TCK, TMS, TDI and TDO used to control the TAP
controller and the boundary scan registers. The TRSTB input is the active-low
reset signal used to reset the TAP controller. TCK is the test clock used to
sample data on input, TDI and to output data on output, TDO. The TMS input is
used to direct the TAP controller through its states. The basic boundary scan
architecture is shown below.
Figure 42: Boundary Scan Architecture
Boundary Scan
TDI
Register
Device Identification
Register
Bypass
Register
Instruction
Register
and
Mux
DFF
TDO
Decode
Control
TMS
Test
Access
Port
Select
Tri-state Enable
Controller
TRSTB