PixArt Imaging Inc.  
ADNS-3090 High-Performance Optical Mouse Sensor  
Shutter_Upper  
Address: 0x0f  
Access: Read  
Reset Value: 0x00  
Bit  
7
6
5
4
3
2
1
0
Field  
S
S
S
S
S
S
S
S
8
15  
14  
13  
12  
11  
10  
9
Data Type: Sixteen bit unsigned integer.  
USAGE: Units are clock cycles. Read Shutter_Upper first, then Shutter_Lower. They should be read consecutively. The  
shutter is adjusted to keep the average and maximum pixel values within normal operating ranges. The shutter value  
is checked and automatically adjusted to a new value if needed on every frame when operating in default mode.  
When the shutter adjusts, it changes by 1/16 of the current value. The shutter value can be set manually by setting  
the AGC mode to Disable using the Extended_Config register and writing to the Shutter_Maximum_Bound registers.  
Because the automatic frame rate feature is related to shutter value. It may also be appropriate to enable the Fixed  
Frame Rate mode using the Extended_Config register.  
Shown below is a graph of 800 sequentially acquired shutter values, while the sensor was moved slowly over white  
paper.  
Shutter Values (White Paper)  
Z =2.4mm, Circle@7.5" diameter, Speed = 6ips  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
1
101  
201  
301  
401  
501  
601  
701  
Counts  
Figure 28. Shutter Value (white paper)  
Shutter vs Z (White Paper)  
Resolution = 3500cpi, Circle@7.5" diameter, Speed = 6ips  
95  
90  
85  
80  
75  
70  
65  
60  
55  
50  
Avg-3sigma  
Avg  
Avg+3sigma  
1.6  
1.8  
2
2.2  
2.4  
2.6  
2.8  
3
3.2  
3.4  
Distance from Lens Reference Plane to Navigation Surface, Z (mm)  
Figure 29. Mean shutter vs. Z (white paper)  
The maximum value of the shutter is dependent upon the setting in the Shutter_Max_Bound_Upper and Shutter_  
Max_Bound_Lower registers.  