PixArt Imaging Inc.  
ADNS-3090 High-Performance Optical Mouse Sensor  
Notes for Motion:  
1. Reading this register freezes the Delta_X and Delta_Y register values. Read this register before reading the Delta_X and Delta_Y registers. If  
Delta_X and Delta_Y are not read before the motion register is read a second time, the data in Delta_X and Delta_Y will be lost.  
2. PixArt Imaging RECOMMENDS that registers 0x02, 0x03 and 0x04 be read sequentially. See Motion burst mode also.  
3. Internal buffers can accumulate more than eight bits of motion for X or Y. If either one of the internal buffers overflows, then absolute path data  
is lost and the OVF bit is set. This bit is cleared once some motion has been read from the Delta_X and Delta_Y registers, and if the buffers are  
not at full scale. Since more data is present in the buffers, the cycle of reading the Motion, Delta_X and Delta_Y registers should be repeated  
until the motion bit (MOT) is cleared. Until MOT is cleared, either the Delta_X or Delta_Y registers will read either positive or negative full scale.  
If the motion register has not been read for long time, at 1800 cpi it may take up to 72 read cycles to clear the buffers, at 3600 cpi, up to 140  
cycles. Alternatively, writing to the Motion_Clear register (register 0x12) will clear all stored motion at once.  
Delta_X  
Address: 0x03  
Access: Read  
Reset Value: 0x00  
Bit  
7
6
5
4
3
2
1
0
Field  
X
X
X
5
X
X
X
X
X
0
7
6
4
3
2
1
Data Type: Eight bit 2’s complement number.  
USAGE: X movement is counts since last report. Absolute value is determined by resolution. Reading clears the register.  
-128  
80  
-127  
81  
-2  
-1  
0
+1  
01  
+2  
02  
+126 +127  
Motion  
Delta_X  
FE  
FF  
00  
7E  
7F  
Delta_Y  
Address: 0x04  
Access: Read  
Reset Value: 0x00  
Bit  
7
6
5
4
3
2
1
0
Field  
Y
Y
Y
Y
Y
Y
Y
Y
0
7
6
5
4
3
2
1
Data Type: Eight bit 2’s complement number.  
USAGE: Y movement is counts since last report. Absolute value is determined by resolution. Reading clears the register.  
-128  
-127  
-2  
-1  
0
+1  
+2  
+126 +127  
Motion  
80  
81  
FE  
FF  
00  
01  
02  
7E  
7F  
Delta_Y  
All rights strictly reserved any portion in this paper shall not be reproduced, copied or transformed to any other forms without permission.  