JT-N
REFERENCE DATA
1. Change of rate of pick-up and drop-out
voltage (at 20°C 68°F)
2. Operate & release time (at 20°C 68°F)
Sample: JTN1S-TMP-F-DC24V (6 pcs.)
3. Operate & release time (at 20°C 68°F)
Sample: JTN1aS-PA-F-DC24V (6 pcs.)
Sample: JTN1S-TMP-F-DC24V (6 pcs.)
40
30
20
10
Drop-out voltage
20
20
Pick-up voltage
Operate time
–55 –35 –15 5 25 45 65 85 105
–67 +41 +221
Operate time
–31 +5
+113+149+185
+77
–10
Ambient
temperature, °C °F
10
10
–20
–30
–40
Max.
Min.
Max.
Min.
Max.
Min.
Release time
Release time
Max.
Min.
0
0
80
90
100 110 120
80
90
100 110 120
Coil applied voltage,%V
Coil applied voltage,%V
4. Distribution frequency of pick-up voltage
(at 20°C 68°F)
Sample: JTN1S-TMP-F-DC12V (30 pcs.)
5. Distribution frequency of drop-out voltage
(at 20°C 68°F)
Sample: JTN1S-TMP-F-DC12V (30 pcs.)
6.-(1) Coil temperature rise (TMP type)*
Ambient temperature: 20°C 68°F
Sample: JTN1aS-TMP-F-DC12V (6 pcs.)
15
10
5
15
10
5
80
20 A
60
10 A
40
20
0
0
0
7.3 7.5 7.7 7.9 8.1 8.3 8.5
3
3.2 3.4 3.6 3.8 4.0 4.2
Drop-out voltage, V
0
80
100
120
140
Coil applied voltage,%V
Pick-up voltage, V
* Coil temperature rise of sealed types are same as
data of the dust cover type.
Ambient temperature: 55°C 131°F
Ambient temperature: 85°C 185°F
Ambient temperature: 105°C 221°F
Sample: JTN1aS-TMP-F-DC12V (6 pcs.)
Sample: JTN1aS-TMP-F-DC12V (6 pcs.)
Sample: JTN1aS-TMP-F-DC12V (6 pcs.)
80
80
60
40
20
0
80
20 A
20 A
10 A
20 A
60
60
10 A
10 A
40
20
0
40
20
0
0
80
100
120
140
0
80
100
120
140
0
80
100
120
140
Coil applied voltage,%V
Coil applied voltage,%V
Coil applied voltage,%V
ASCTB187E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/