“ZNR” Transient/Surge Absorbers (Type D)
14 Series
■ Ratings and Characteristics
● Operating Temperature Range : 40 to 85
–
°C
–
°C
● Storage Temperature Range : 40 to 125
Maximum
Peak Current
(8/20 µs)
Clamping
Voltage
(max.)
✽Ip
Maximum
Energy
Maximum
Allowable
Voltage
Varistor
Voltage
Rated
Power
Capacitance
(max.)
Part No.
(10/1000 µs) (2 ms) 1 time 2 times
1 mA
V
(V)
ACrms (V) DC (V)
(V)
(W)
(J)
5.2
(J)
(A)
(A) @1 kHz (pF)
ERZV14D180
ERZV14D220
ERZV14D270
ERZV14D330
ERZV14D390
ERZV14D470
ERZV14D560
ERZV14D680
ERZV14D820
ERZV14D101
ERZV14D121
ERZV14D151
18(16 to 20)
22(20 to 24)
27(24 to 30)
33(30 to 36)
39(35 to 43)
47(42 to 52)
56(50 to 62)
68(61 to 75)
82(74 to 90)
100(90 to 110)
120(108 to 132)
150(135 to 165)
11
14
14
18
36
43
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
4.3 2000 1000
5.3 2000 1000
6.5 2000 1000
7.9 2000 1000
9.4 2000 1000
25000
20000
16000
12200
7000
6750
6500
5500
3700
3200
2700
2200
770
6.3
7.8
9.5
17
22
53
20
26
65
25
31
77
11
30
38
93
14
16
11
2000 1000
2000 1000
2000 1000
6000 5000
6000 5000
6000 5000
35
45
110
13
16
20
25
30
40
56
135
135
165
200
250
340
360
395
455
545
595
650
710
775
845
1025
1120
1240
1355
1500
1650
1815
2970
20
50
65
28
60
85
35
75
100
125
170
180
200
225
270
300
320
350
385
410
505
560
615
670
745
825
895
1465
42
95
53
37.5 6000 5000
ERZV14D201 200(185 to 225)
ERZV14D221 220(198 to 242)
130
140
150
175
210
230
250
275
300
320
385
420
460
510
550
625
680
1000
70
50
55
6000 5000
6000 5000
6000 5000
6000 5000
6000 4500
6000 4500
6000 4500
6000 4500
6000 4500
6000 4500
5000 4500
5000 4500
5000 4500
5000 4500
5000 4500
5000 4500
5000 4500
5000 4500
78
740
ERZV14D241
240(216 to 264)
84
60
700
ERZV14D271 270(247 to 303)
ERZV14D331 330(297 to 363)
ERZV14D361 360(324 to 396)
ERZV14D391 390(351 to 429)
ERZV14D431 430(387 to 473)
99
70
640
115
130
140
155
175
190
190
190
210
235
255
280
310
510
80
580
90
540
100
110
125
136
136
136
150
165
180
200
220
360
500
450
ERZV14D471
ERZV14D511
470(423 to 517)
510(459 to 561)
400
350
ERZV14D621 620(558 to 682)
ERZV14D681 680(612 to 748)
330
320
ERZV14D751
750(675 to 825)
310
ERZV14D821 820(738 to 902)
ERZV14D911 910(819 to 1001)
ERZV14D102 1000(900 to 1100)
ERZV14D112 1100(990 to 1210)
ERZV14D182CS 1800(1700 to 1980)
280
250
230
210
120
✽Ip Measuring current of clamping voltage 180 to 680 : 10 A, 820 to 182 : 50 A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
00 Sep. 2010
– 313 –