Terminal Block Type
Note:Terminal Block without EMC Filter (Suffix-T) and Terminal Block with EMC Filter (Suffix-TF)
The terminal block type of HAE100 can meet the EMC characteristics with an EMC filter. Followings are the mechanical drawings for
reference. Pin assignments are same as standard type.
1) Terminal Block without EMC Filter (Suffix-T)
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by using the
method shown below.
TRIM UP
7
TRIM DOWN
6
RU
RD
8
7
TERMINAL CONNECTION
Terminal
Define
- INPUT
CASE
wire range
1
2
3
4
5
6
7
8
9
14 AWG to 16 AWG
14 AWG to 18 AWG
14 AWG to 18 AWG
14 AWG to 16 AWG
10 AWG to 12 AWG
14 AWG to 18 AWG
14 AWG to 18 AWG
14 AWG to 18 AWG
10 AWG to 12 AWG
CTRL
+ INPUT
- OUTPUT
- SENSE
TRIM
+ SENSE
+ OUTPUT
2) Terminal Block with EMC Filter (Suffix-TF)
All dimensions in inches (mm)
Tolerance : x.xx±0.02 (x.x±0.5)
x.xxx±0.01 (x.xx±0.25)
Page 5 of 5 Issued Date:2009/01/13