OXU140CM Data Sheet
Oxford Semiconductor, Inc.
Power
Consumption
Table 12 gives typical power consumption figures for the OXU140CM.
Table 12 OXU140CM Power Consumption
Condition
Host operational current
Peripheral operational current
ENVREG = 1
High-speed,
ENVREG = 1
Full-speed,
ENVREG = 1
Host suspend state current
Peripheral suspend state current
MMC host operational current
MMC host suspend current
Power save state current
ENVREG = 1
ENVREG = 1
ENVREG = 1
ENVREG = 1
ENVREG = 1
Min
Max
30
75
50
150 (typical)
400 (typical)
45
150 (typical)
150 (typical)
Unit
mA
mA
mA
µA
µA
mA
µA
µA
The above measurements are at typical process corner and room
temperature and do not account for process and temperature variations.
Peripheral operational current is measured with a 5 m cable with
maximum switching and BULK OUT transfers at 400 Mbps with 92.6%
bus utilization during one microframe. The actual average current in
customer applications will be lower.
MMC host operation current is measured with 8‐bit at 48 MHz writing
55AA pattern to an MMC 4.1 card at 15 Mbps throughput. The actual
average operational current will vary base on the data pattern and
throughput rates supported by the attached device.
ENVREG = 1 enables the internal voltage regulator.
8
External--Free Release
DS-0038 Jul 06