ADM1032  
1
9
1
9
SCLK  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
A6  
A5  
A4  
A3  
A2  
A1  
A0  
R/W  
D7  
SDATA  
START BY  
MASTER  
ACK. BY  
ADM1032  
ACK. BY  
ADM1032  
FRAME 2  
FRAME 1  
ADDRESS POINTER REGISTER BYTE  
SERIAL BUS ADDRESS BYTE  
1
9
SCLK (CONTINUED)  
SDATA (CONTINUED)  
D2  
D7  
D6  
D5  
D4  
D3  
D1  
D0  
ACK. BY STOP BY  
ADM1032 MASTER  
FRAME 3  
DATA BYTE  
Figure 13. Writing a Register Address to the Address Pointer Register,  
then Writing Data to the Selected Register  
1
9
1
9
SCLK  
A6  
A5  
A4  
A3  
A2  
A1  
A0 R/W  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
SDATA  
ACK. BY  
ADM1032  
ACK. BY STOP BY  
ADM1032 MASTER  
START BY  
MASTER  
FRAME 1  
SERIAL BUS ADDRESS BYTE  
FRAME 2  
ADDRESS POINTER REGISTER BYTE  
Figure 14. Writing to the Address Pointer Register Only  
19  
1
9
SCLK  
SDATA  
START BY  
A6  
A5  
A4  
A3  
A2  
A1  
A0  
R/W  
ACK. BY  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
ACK. BY STOP BY  
ADM1032 MASTER  
ADM1032  
MASTER  
FRAME 1  
SERIAL BUS ADDRESS BYTE  
FRAME 2  
DATA BYTE FROM ADM1032  
Figure 15. Reading Data from a Previously Selected Register  
MASTER  
RECEIVES  
SMBALERT  
ALERT Output  
The ALERT output goes low whenever an outoflimit  
measurement is detected, or if the remote temperature sensor  
is opencircuit. It is an open drain and requires a pullup to  
ALERT RESPONSE  
ADDRESS  
DEVICE  
ADDRESS  
NO  
ACK  
START  
RD ACK  
STOP  
MASTER SENDS  
ARA AND READ  
COMMAND  
V
DD  
. Several ALERT outputs can be wireOR’ed together  
DEVICE SENDS  
ITS ADDRESS  
so that the common line goes low if one or more of the  
ALERT outputs goes low.  
Figure 16. Use of SMBALERT  
The ALERT output can be used as an interrupt signal to a  
processor, or it can be used as an SMBALERT. Slave devices  
on the SMBus can not normally signal to the master that they  
want to talk, but the SMBALERT function allows them to do  
so.  
One or more ALERT outputs can be connected to a  
common SMBALERT line connected to the master. When  
the SMBALERT line is pulled low by one of the devices, the  
following procedure occurs (see Figure 16).  
1. SMBALERT is pulled low.  
2. Master initiates a read operation and sends the  
alert response address (ARA = 0001 100). This is  
a general call address that must not be used as a  
specific device address.  
3. The device whose ALERT output is low responds  
to the alert response address and the master reads  
its device address. Since the device address is  
http://onsemi.com  