 浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第24页浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第25页浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第26页浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第27页浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第29页浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第30页浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第31页浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第32页  
Track Mounting Accessories (Order Separately)  
Mounting Track  
PFP-100N  
PFP-50N  
PFP-100N2  
16  
±0.15  
±0.3  
7.3  
4.5  
4.5  
±0.15  
27  
35  
±0.3  
35  
27 24  
29.2  
1.5  
15 25  
10  
25  
25  
25  
15 (5) *  
1
15 25  
25  
25  
25 15  
1
10  
10  
10  
1,000 (500) *  
* The numbers in parentheses () are dimensions for the PFP-50N.  
1,000  
End Plate  
Spacer  
16  
12  
10  
5
6.2  
1.8  
PFP-M  
PFP-S  
M4 × 8  
pan-head  
1
screw  
34.8  
50  
35.5 35.3  
44.3  
1.8  
11.5  
10  
M4 spring washer  
1.3  
4.8  
16.5  
Precautions when Selecting ZEN Programmable Relays  
Changes in Comparison with Previous Models  
The power supply and transistor output voltage ranges for CPU Units and Expansion I/O Units with DC power supply has been expanded to  
10.8 to 28.8 VDC.  
The width of Expansion I/O Units has been reduced by half and only 8-point models are available.  
The connection method between the CPU Unit and Expansion I/O Units has changed.  
Twin timer operation has been added to timers.  
Multiple-day operation and pulse-output operation has been added to weekly timers.  
An 8-digit counter and 8-digit comparators have been added.  
The accuracy of analog inputs has been increased to ±1.5% FS.  
The timing accuracy of weekly timers and calendar timers has been increased to ±15 s or less per month (at 25°C).  
Australia and New Zealand Daylight Saving Time (DST) settings have been added.  
CPU Units with RS-485 communications and economic CPU Units have been added.  
The heat slits in the cases of CPU Units and Expansion I/O Units have been removed to prevent foreign matter from entering.  
Model numbers have been changed to reflect the improved functionality.  
Previous Model Numbers  
ZEN-@C@@@-@  
ZEN-@C@@@-@-V1  
ZEN-@E@@  
(Pre-V1 CPU Units)  
(V1 CPU Units)  
(4E/8E-type Expansion I/O Units)  
New Model Numbers  
ZEN-@C@@@-@-V2  
ZEN-8E1@@  
(V2 CPU Units)  
(8E1-type Expansion I/O Unit)  
Memory Cassettes, Connecting Cables, and Battery Units have not been changed and can be used as they are with the new models.  