■ Characteristics
Operating speed
0.1 mm to 1 m/s (plunger models)
Operating frequency
Mechanical: 600 operations/minute, max.
Electrical: 30 operations/minute, max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
15 mΩ max.
Dielectric strength (see note 2)
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
V-21, V-16 and V-11:
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between
each terminal and non-current-carrying metal parts
V-15 and V-10:
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between
each terminal and non-current-carrying metal parts
Vibration resistance (see note 3)
Shock resistance (see note 3)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s2 (approx. 100G) max.
Malfunction:
V-21/V-16/V-15:
300 m/s2 (approx. 30G) max.
V-11/V10:
200 m/s2 (approx. 20G) max.
Life expectancy
Mechanical: 50,000,000 operations min. (60 operations/minute)
Electrical: V-21/V-16/V-15:
100,000 operations min. (30 operations/minute)
(V-15 heat resistive: 20,000 operations min. (30 ops/minute))
300,000 operations min. (30 operations/minute)
V-11/V-10:
(V-10 heat resistive: 50,000 operations min. (30 ops/minute))
Degree of protection
IEC IP40
Degree of protection against electric shock Class I
Proof tracking index (PTI)
175
Ambient operating temperature
-25
-25
°
C to 80
°
C (at 60% RH max.) with no icing
C for heat resistive models (at 60% RH max.) with no icing.
°C to 150
°
Ambient operating humidity
Weight
85% max. (for 5°C to 35°C)
Approx. 6.2 g (plunger models)
Note: 1. Data shown are of initial value.
2. The dielectric strength shown is measured using a separator between the switch and metal mounting plate.
3. For pin plunger models, the above values apply for use at both the free position and total travel position. For lever models, they apply at
the total travel position.
4. For testing conditions, contact your OMRON sales representative.
■ Contact Specifications
Item
V-21
V-16
V-15
V-11
V-10
Contact
Specification
Material
Rivet
Silver alloy
Silver
Gap
(standard value)
1 mm (F gap type) or 0.5 mm (G gap type)
Inrush current
NC
NO
50 A max.
40 A max.
36 A max.
24 A max.
Minimum applicable load
160 mA at 5 VDC
Note: Minimum applicable loads are indicated by N standard reference values. This value represents the failure rate at a 60% (λ60) reliability level
-6
(JIS C5003). The equation λ60=0.5 x 10 / operations indicates that a failure rate of 1/2,000,000 operations can be expected at a reliability
level of 60%
126