Specifications
■ Ratings
Coil Ratings
Rated voltage
Rated current
Coil resistance
Must operate
voltage
Must release
voltage
Max. voltage
Power
consumption
50 Hz
443 mA
221 mA
110 mA
24.2 mA
22.2 mA
12.1 mA
11.5 mA
11.0 mA
224 mA
112 mA
55.8 mA
28.1 mA
13.5 mA
12.3 mA
60 Hz
385 mA
193 mA
96.3 mA
21.0 mA
19.3 mA
10.5 mA
10.0 mA
9.6 mA
AC
6 V
3.1 Ω
80% max. of rated 30% min. of rated 110% of rated volt- Approx. 2.3 VA
voltage
voltage at 60 Hz age
25% min. of rated
voltage at 50 Hz
at 60 Hz
Approx. 2.7 VA
at 50 Hz
12 V
24 V
110 V
120 V
220 V
230 V
240 V
6 V
13.7 Ω
48.4 Ω
932 Ω
1,130 Ω
3,550 Ω
4,250 Ω
4,480 Ω
26.7 Ω
107 Ω
DC
15% min. of rated
voltage
Approx. 1.4 W
12 V
24 V
48 V
100 V
110 V
430 Ω
1,710 Ω
7,390 Ω
8,960 Ω
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/−20% for AC rated current and
±15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. The maximum voltage is one that is applicable instantaneously to the Relay coil at 23°C and not continuously.
4. For DC-operated Relays with the LED indicator built-in, add an LED current of approx. 5 mA to the rated current.
Contact Ratings
Load
Resistive load
(cosφ = 1)
Inductive load
(p.f. = 0.4)
Contact mechanism
Contact material
Rated load
Single
AgSnIn
NO 10 A, 250 VAC
7 A, 250 VAC
10A, 30 VDC
NC 5 A, 250 VAC
5 A, 30 VDC
Rated carry current
10 A
Max. switching voltage
Max. switching current
Max. switching capacity
250 VAC, 250 VDC
10 A
NO 2,500 VA/300 W
NC 1,250 VA/150 W
General Purpose Relays MKS