New H7ET
Specifications
■ General
Item
H7ET-NV-@
H7ET-NFV-@
H7ET-N-@
H7ET-NV1-@
H7ET-NFV1-@
H7ET-N1-@
H7ET-NV-@H
Accumulating
H7ET-NV1-@H
Operating mode
Mounting method
External connections
Reset
Flush mounting
Screw terminals
External/Manual reset
Display
7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 1)
7
Number of digits
Time range
0.0h to 999999.9h ←→ 0.0h to 3999d23.9h
0s to 999h59min59s ←→ 0.0min to 9999h59.9min
(switchable with switch)
(switchable with switch)
Timer input
PNP/NPN univer- AC/DC multi-volt- No-voltage input PNP/NPN univer- AC/DC multi-volt- No-voltage input
sal DC voltage in- age input
put
(see note 2)
sal DC voltage in- age input
put
Case color
Light gray or black (-B models)
Attachment
Waterproof packing, Y92F-34 Flush Mounting Bracket, time unit labels (see note 3)
Approved standard
UL863, CSA C22.2 No.14, Lloyds
Conforms to EN61010-1/IEC61010-1 (pollution degree2/overvoltage category III)
Conforms to VDE0106/P100
Note: 1. Only PNP/NPN universal DC voltage input models (-H models) have a backlight.
2. The frequency range for an AC voltage is 50 to 60 Hz.
3. “-hours”, “-d-h”, “-h-m”, and “-h-m-s” labels are included.
4. Zero suppression: Zeros are not displayed to increase readability. For example, "000008.2" is displayed as "8.2" if zero suppression is
set. If the range is set to 3999d23.9h, the value is "008.2".
■ Ratings
Item
H7ET-NV@-@
H7ET-NFV@-@
H7ET-N@-@
H7ET-NV@-@H
Supply voltage
Backlight model: 24 VDC (0.3 W max.) Not required (powered by built-in battery)
(for backlight)
No-backlight model: Not required (pow-
ered by built-in battery)
Timer input
Reset input
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC
(Input impedance: Approx. 4.7 kΩ)
High (logic) level: 24 to 240 VAC/VDC, No voltage input
50/60 Hz
Maximum short-circuit impedance:
Low (logic) level: 0 to 2.4 VAC/VDC, 50/ 10 kΩ max.
60 Hz
Short-circuit residual voltage: 0.5 V max.
Minimum open impedance: 750 kΩ min.
No voltage input
Maximum short-circuit impedance:
10 kΩ max.
Short-circuit residual voltage: 0.5 V max.
Minimum open impedance: 750 kΩ min.
Minimum pulse
width
1 s
Reset system
External reset and manual reset: Minimum signal width of 20 ms
0.98 N·m max.
Terminal screw
tightening torque
Ambient tempera- Operating: –10°C to 55°C (with no condensation or icing)
ture Storage: –25°C to 65°C (with no condensation or icing)
Ambient humidity Operating: 25% to 85%
10