Specifications  
Ratings  
Coil Ratings (per G6B Relay)  
Rated voltage  
5 VDC  
12 VDC  
19.1 mA  
720  
24 VDC  
10.7 mA  
2,880 Ω  
Rated current  
35.5 mA  
Coil resistance  
125 Ω  
Must operate voltage  
Must release voltage  
Max. voltage  
80% max. of rated voltage  
10% min. of rated voltage  
130% of rated voltage  
Approx. 200 mW  
Power consumption  
Note: 1. Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of 20%.  
2. Operating characteristics were measured at a coil temperature of 23°C.  
3. The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply. There is  
no continuous allowance.  
4. Diodes to absorb coil surge are equivalent to S5688J (reverse voltage resistance: 600 V; forward current: 1 A).  
Contact Ratings  
Classification  
Load  
G6B-4BND (standard), G6B-47BND (long-life)  
G6B-48BND (high-reliability)  
Resistive load Inductive load  
(cosφ = 0.4, L/R = 7 ms) (cosφ = 1)  
Resistive load  
Inductive load  
(cosφ = 1)  
(cosφ = 0.4, L/R = 7 ms)  
Rated load  
5 A at 250 VAC,  
5 A at 30 VDC  
2 A at 250 VAC,  
2 A at 30 VDC  
2 A at 250 VAC,  
2 A at 30 VDC  
0.5 A at 250 VAC,  
0.5 A at 30 VDC  
Rated carry current  
5 A  
2 A  
Max. switching voltage  
Max. switching current  
Max. switching power  
380 VAC, 125 VDC  
5 A  
2 A  
1,250 VA, 150 W  
500 VA, 60 W  
500 VA, 60 W  
1 mA at 1 VDC  
125 VA, 15 W  
Error rate (reference value) (see note) 10 mA at 5 VDC  
Note: This value fulfills the P reference value of opening/closing at a rate of 120 times per min (ambient operating environment and determination  
criteria according to JIS C5442).  
Characteristics  
Contact resistance (see note 2)  
100 mmax.  
Operate time  
10 ms max. (approx. 3 ms)  
15 ms max. (approx. 4 ms)  
Release time  
Switching power  
Mechanical: 18,000 operations/hr  
Rated load: 1,800 operations/hr  
Insulation resistance  
Dielectric strength  
1,000 Mmin. (at 500 VDC)  
2,000 VAC, 50/60 Hz for 1 min between coil and contacts  
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity  
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity  
250 VAC, 50/60 Hz for 1 min between coils of different polarity  
Vibration resistance  
Shock resistance  
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)  
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)  
Destruction: 1,000 m/s2 (approx. 100G)  
Malfunction: 100 m/s2 (approx. 10G)  
Endurance  
Mechanical: 50,000,000 operations min. (at 18,000 operations/hr)  
Electrical: 100,000 operations min. (at 1,800 operations/hr, rated load)  
500,000 operations min. for long-life at 2 A  
100,000 operations min for long-life at 5 A  
Ambient temperature  
Operating: –25°C to 55°C (with no icing or condensation)  
Storage: –25°C to 55°C (with no icing or condensation)  
Operating: 35% to 85%  
Ambient humidity  
Weight  
Approx. 75 g  
Note: 1. The above values are initial values.  