Specifications
■ Ratings
Coil Ratings (per G6B Relay)
Rated voltage
5 VDC
12 VDC
19.1 mA
720 Ω
24 VDC
10.7 mA
2,880 Ω
Rated current
35.5 mA
Coil resistance
125 Ω
Must operate voltage
Must release voltage
Max. voltage
80% max. of rated voltage
10% min. of rated voltage
130% of rated voltage
Approx. 200 mW
Power consumption
Note: 1. Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of 20%.
2. Operating characteristics were measured at a coil temperature of 23°C.
3. The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply. There is
no continuous allowance.
4. Diodes to absorb coil surge are equivalent to S5688J (reverse voltage resistance: 600 V; forward current: 1 A).
Contact Ratings
Classification
Load
G6B-4BND (standard), G6B-47BND (long-life)
G6B-48BND (high-reliability)
Resistive load Inductive load
(cosφ = 0.4, L/R = 7 ms) (cosφ = 1)
Resistive load
Inductive load
(cosφ = 1)
(cosφ = 0.4, L/R = 7 ms)
Rated load
5 A at 250 VAC,
5 A at 30 VDC
2 A at 250 VAC,
2 A at 30 VDC
2 A at 250 VAC,
2 A at 30 VDC
0.5 A at 250 VAC,
0.5 A at 30 VDC
Rated carry current
5 A
2 A
Max. switching voltage
Max. switching current
Max. switching power
380 VAC, 125 VDC
5 A
2 A
1,250 VA, 150 W
500 VA, 60 W
500 VA, 60 W
1 mA at 1 VDC
125 VA, 15 W
Error rate (reference value) (see note) 10 mA at 5 VDC
Note: This value fulfills the P reference value of opening/closing at a rate of 120 times per min (ambient operating environment and determination
criteria according to JIS C5442).
■ Characteristics
Contact resistance (see note 2)
100 mΩ max.
Operate time
10 ms max. (approx. 3 ms)
15 ms max. (approx. 4 ms)
Release time
Switching power
Mechanical: 18,000 operations/hr
Rated load: 1,800 operations/hr
Insulation resistance
Dielectric strength
1,000 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
250 VAC, 50/60 Hz for 1 min between coils of different polarity
Vibration resistance
Shock resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 100 m/s2 (approx. 10G)
Endurance
Mechanical: 50,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr, rated load)
500,000 operations min. for long-life at 2 A
100,000 operations min for long-life at 5 A
Ambient temperature
Operating: –25°C to 55°C (with no icing or condensation)
Storage: –25°C to 55°C (with no icing or condensation)
Operating: 35% to 85%
Ambient humidity
Weight
Approx. 75 g
Note: 1. The above values are initial values.
2. Measurement condition: 1 A at 5 VDC
Terminal Relay G6B-4@@ND