Specifications
■ Coil Ratings
Rated voltage
12 VDC
24 VDC
10.4 mA
2,304 Ω
Rated current
20.8 mA
Coil resistance
576 Ω
Must operate voltage
Must release voltage
Max. permissible voltage
Power consumption
80% of rated voltage max.
10% of rated voltage min.
150% of rated voltage (at 23°C)
250 mW (other options available)
Note: 1. Each rated current or coil resistance value must allow a tolerance of ±10% at a coil temperature of 23°C.
2. The operating characteristics are values at a coil temperature of 23°C.
3. The maximum permissible voltage is the maximum voltage that is applicable to the relay coil for an instant.
■ Contact Ratings
Rated load (capacitive load)
250 VAC with inrush current of 100 A (0 to peak) and constant current of 3 A (rms)
Resistive load (reference value) 10 A @ 250 VAC; 5A @ 30 VDC/277 VAC (@40° C)
Max. switching voltage
Max. switching current
277 VAC, 30 VDC
10 A (@40°C)
■ Characteristics
Contact resistance (see note 2)
100 mΩ max.
15 ms max.
5 ms max.
Operate time
Release time
Insulation resistance (see note 3) 1,000 MΩmin. (at 500 VDC)
Dielectric strength
4,000 VAC 50/60 Hz for 1 min between coil and contacts
1,000 VAC 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage
Vibration resistance
10 kV (1.2 x 50 µs between coil and contacts), 12 kV optional
Destruction:10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction:10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction:1,000 m/s2
Malfunction: 200 m/s2
Shock resistance
Endurance
Mechanical: 1,000,000 operations min. (at 18,000 operations an hour)
Electrical: 40,000 operations min. with a rated load at a 1,800 operations an hour.
100,000 operations min. with a resistive load (reference value)
Operating: -40°C to 70°C (with no icing)
Operating: 5% to 85%
Ambient temperature
Ambient humidity
Weight
Approx. 10 g
■ Approved Standards
UL (File No. E41515, UL508)
CSA (File No. LR31928, C22.2 No. 14)
Model
Coil ratings
5 to 24 VDC (@40°C)
Contact ratings
5 A, 277 VAC
Number of test operations
30,000
G5PA-1
5 A, 30 VDC
6,000
30,000 (optional)
100,000
10 A, 250 VAC
TV-5 rating
25,000
TV-8 rating
25,000 (optional)
2
Special-purpose PCB Relay G5PA-1