E52
Enclosed-terminal Models
E52-P@C
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
98
34 dia.
Aluminum die-cast terminal box
57
22 dia.
SUS316 protective tubing
SUS316 protective tubing
10
10 dia.
8 dia.
90
65
14 dia.
10
40 dia.
Aluminum die-cast terminal box
(See note 1.)
Cap
35
L − 40
(See note 2.)
L − 50
Cap
G3/8, 19 mm between
facing sides, 10 inner
dia. (with 7-inner-dia.
rubber bushing built-in)
57
/2, 15-A ground (with 11-inner-dia.
Use wiring terminals that fit M3 screws.
G1
rubber bushing built-in)
Use wiring terminals that fit M4 screws.
Note: 1. The length L is in centimeters, but “40” is 40 millimeters.
Therefore, for the E52-P20C, L = 20 (cm), the protective tubing length L − 40 = 200 − 40 = 160 mm.
2. The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-P75C: L = 75 (cm), the protective tubing length L − 50 = 750 − 50 = 700 mm.
3. Terminal box: The permissible temperature is 0°C to 80°C.
Model Information
Custom-made models are available on request. Refer to page 4 for details.
Terminal type
Protective tubing
length L (cm)
Protective tubing diameter D (mm)
8 dia.
10 dia.
Model
Enclosed-terminal
Models
20
E52-P20C D=8
E52-P35C D=8
E52-P50C D=8
---
---
35
E52-P35C D=10
E52-P50C D=10
E52-P75C D=10
E52-P100C D=10
50
75
100
---
Note: The terminals in the cap indicate polarity (A, B, b).