Ratings / Characteristics of AC Switching Models
Item
Sensing method
Power supply voltage
Current consumption
Rated sensing distance[1.]
Typical sensing distance for dif-
ferent reflector types [2.]
Detectable object
Directional angle
Differential travel
Response time
Control output
Power reset time
Ambient illumination
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Enclosure rating
Light source
Indicators
Sensitivity adjustment
Connection method
Operation mode
Circuit protection
Weight (approx.)
Housing materials
E3F2-3Z1
E3F2-3Z2
Through-beam
24 to 240 VAC ±10%, 50 / 60 Hz
10 mA max.
3m
–
5 mA max.
0.1 - 2 m
(with reflector E39-R1)
E39-R1: 3,4 m
E39-R7: 3,9 m
E39-R8: 5,2 m
Opaque object: 56 mm min.
0.1 m
(5 x 5 cm white mat paper)
–
E3F2-R2Z1
E3F2-R2Z2
Non-polarizing Retroreflective
E3F2-DS10Z1
E3F2-DS10Z2
Diffuse reflective
(wide-beam characteristic)
Opaque object: 11 mm min.
3° to 20°
–
30 ms max.
Opaque objects
–
20% max.
AC solid state (SCR) 200 mA max.; residual voltage: 5 V max. at 200 mA
100 ms
Incandescent lamp: 3000 lx max. Sunlight: 10000 lx max.
Operating: -25 to 55 °C / Storage: -30 to 70 °C (with no icing or condensation)
Operating: 35% to 85% / Storage: 35% to 95% (without condensation)
20 MΩ min. at 500 V DC between energized parts and case
1500 VAC, 50 / 60 Hz for 1 min between energized parts and case
10 to 55 Hz, 1.5 mm double amplitude for 2 hrs each direction (X, Y, Z)
500 m/sqr (approx. 50 g) for each direction (X, Y, Z)
IP67 [3.]; NEMA 1, 2, 4
Infrared LED (880 nm)
Light incident/power indicator for light source (red)
Fixed
2 m, 5 m pre-wired cable (PVC dia. 4 mm (14 / 0.15))
Light-ON or Dark-ON (fixed)
None
110 g (pre-wired 2 m cable)
Plastic (case: ABS; lens: PMMA)
Note: 1.
For stable sensing distance in detail, please refer to “Engineering Data”
2.
Typical sensing distance corresponds to 80% of the max. sensing distance.
3.
The enclosure rating IP67 of OMRON internal standards correspond to stricter test requirements than the standard IEC 60529 (refer to
chapter “Precautions”)