E2E2-X@Y@ AC 2-wire Models
Size
M12
M18
M30
Type
Shielded
Unshielded
Shielded
Unshielded
Shielded
E2E2-X10Y@
10 mm 10%
0 to 8.0 mm
Unshielded
Item
Sensing distance
Set distance
E2E2-X2Y@
2 mm 10%
0 to 1.6 mm
E2E2-X5MY@
5 mm 10%
0 to 4.0 mm
E2E2-X5Y@
5 mm 10%
0 to 4.0 mm
E2E2-X10MY@
10 mm 10%
0 to 8.0 mm
E2E2-X18MY@
18 mm 10%
0 to 14.0 mm
Differential travel
Sensing object
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to Engineering Data.)
Standard sensing object Iron, 12 x 12 x
Iron, 15 x 15 x
1 mm
Iron, 18 x 18 x
1 mm
Iron, 30 x 30 x
1 mm
Iron, 30 x 30 x
1 mm
Iron, 54 x 54 x
1 mm
1 mm
Response speed
25 Hz
Power supply voltage
(operating voltage
range) (See note 1.)
24 to 240 VAC, 50/60 Hz (20 to 264 VAC)
Leakage current
1.7 mA max.
Control
output
Load
5 to 200 mA
5 to 300 mA
current
(See note
2.)
Residual
voltage
Refer to Engineering Data.
Indicator
Operation indicator (red LED)
Operation mode (with
sensing object
approaching)
Y1 Models: NO
Y2 Models: NC
For details, refer to Timing Charts.
Ambient temperature
Ambient humidity
Operating/Storage: –40°C to 85°C (with no icing or condensation) (See notes 1 and 2.)
Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
15% max. of sensing distance at 23°C in the temperature range of –40°C to 85°C
10% max. of sensing distance at 23°C in the temperature range of –25°C to 70°C
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
1% max. of sensing distance in the rated voltage range 15%
50 MΩ min. (at 500 VDC) between current-carrying parts and case
4,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
1,000 m/s2, 10 times each in X, Y, and Z directions
Degree of protection
IEC 60529 IP67
In-house standard for oil resistance (former JEM standard equivalent to IP67g) (See note 3.)
Connection method
Pre-wired models (standard length: 2 m)
Weight (packed state)
Approx. 65 g
Approx. 150 g
Approx. 210 g
Material
Case
Brass
Sensing
surface
PBT (polybutylene terephthalate)
Clamping
nuts
Brass-nickel plated
Iron-zinc plated
Toothed
washer
Accessories
Instruction manual
Note 1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is –25°C to 85°C.
2. When using an M18-or M30-sized E2E2 within an ambient temperature of 70°C to 85°C, make sure that the E2E2 has a control output of
5 to 200 mA maximum.
3. This OMRON in-house standard confirms resistance to cutting and other oils. It is equivalent to the former JEM standard.
E2E/E2E2 Cylindrical Proximity Sensor