E2E-X@Y@ AC 2-wire Models
Size
Type
Item
Sensing distance
Set distance
Differential travel
Sensing object
Standard sensing
object
Response speed
Power supply
voltage (operating
voltage range)
(See note 1.)
Leakage current
Control Load
output current
(See note
2.)
Residual
voltage
Indicator
Shielded
M8
Unshielded
M12
Shielded
E2E-X2Y@
2 mm
±
10%
0 to 1.6 mm
Unshielded
M18
Shielded
E2E-X5Y@
5 mm
±
10%
0 to 4.0 mm
Unshielded
E2E-X10MY@
M30
Shielded
Unshielded
E2E-X1R5Y@
E2E-X2MY@
E2E-X5MY@
5 mm
±
10%
0 to 4.0 mm
E2E-X10Y@
E2E-X18MY@
0 to 8.0 mm
0 to 14.0 mm
1.5 mm
±
10% 2 mm
±
10%
0 to 1.2 mm
0 to 1.6 mm
10% max. of sensing distance
10 mm
±
10% 10 mm
±
10% 18 mm
±
10%
0 to 8.0 mm
Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to
Engineering Data.)
Iron, 8 x 8 x
1 mm
25 Hz
24 to 240 VAC, 50/60 Hz (20 to 264 VAC)
Iron,12 x 12 x Iron, 12 x 12 x Iron, 15 x 15 x Iron, 18 x 18 x Iron, 30 x 30 x Iron, 30 x 30 x Iron, 54 x 54 x
1 mm
1 mm
1 mm
1 mm
1 mm
1 mm
1 mm
1.7 mA max.
5 to 100 mA
5 to 200 mA
5 to 300 mA
Refer to
Engineering Data.
Operation indicator (red LED)
Operation mode
Y1 Models: NO
(with sensing object
Y2 Models: NC
approaching)
For details, refer to
Timing Charts.
Protection circuit
Surge suppressor
Ambient temperature
Operating/Storage: –25
°
C to Operating/Storage: –40
°
C to 85
°
C (with no icing or condensation)
(See notes 1 and 2.)
70
°
C (with no icing or
condensation)
Ambient humidity
Temperature
influence
Operating/Storage: 35% to 95% (with no condensation)
±
10% max. of sensing
±
15% max. of sensing distance at 23
°
C in the temperature range of –40
°
C to 85
°
C
distance at 23
°
C in the
±
10% max. of sensing distance at 23
°
C in the temperature range of –25
°
C to 70
°
C
temperature range of –25
°
C
to 70
°
C
±
1% max. of sensing distance in the rated voltage range
±
15%
4,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case (2,000 VAC for M8 Models)
500 m/s
2
10 times each in X, 1,000 m/s
2
10 times each in X, Y, and Z directions
Y, and Z directions
note 3.)
Voltage influence
Dielectric strength
Shock resistance
Insulation resistance
50 M
Ω
min. (at 500 VDC) between current-carrying parts and case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Degree of protection
IEC 60529 IP67 (Pre-wired models: in-house standard for oil resistance (former JEM standard equivalent to IP67g))
(See
Connection method
Weight Pre-wired
(packed models
state)
Connector
models
Material Case
Sensing
surface
Clamping
nuts
Toothed
washer
Accessories
Pre-wired models (standard length 2 m), connector models
Approx. 60 g
Approx. 15 g
Stainless steel (SUS303)
Approx. 70 g
Approx. 25 g
Brass-nickel plated
Approx. 130 g
Approx. 40 g
Approx. 175 g
Approx. 90 g
PBT (polybutylene terephthalate)
Brass-nickel plated
Iron-zinc plated
Instruction manual
Note 1.
When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is over –25
°
C.
2.
When using an M18-or M30-sized E2E within an ambient temperature of 70
°
C to 85
°
C, make sure that the E2E has a control output of 5
to 200 mA max.
3.
This OMRON in-house standard confirms resistance to cutting and other oils. It is equivalent to the former JEM standard.
E2E/E2E2
Cylindrical Proximity Sensor
11