WARNING
This product is not designed or rated for ensuring safety
of persons.
Do not use it for such purposes.
■ Precautions for Safe Use
The colors in parentheses are previous wire colors.
Item
Examples
DC 2-wire Models
Power supply
DC 3-wire Models
Do not impose an excessive voltage on the
E2E/E2E2, otherwise it may explode or burn.
Do not impose 100 VAC on any E2E/E2E2
DC Model, otherwise it may explode or burn.
Load
Brown
Brown
Load
Sensor
Blue
Incorrect
Incorrect
Sensor
Black
Blue
Load short-circuit
DC 2-wire Models
DC 3-wire Models (NPN output)
Do not short-circuit the load, or the E2E/E2E2
may explode or burn.
The following diagram shows that the load is
short-circuited while the polarity of the supply
voltage imposed on the E2E/E2E2 is wrong,
in which case the E2E/E2E2 may explode or
Brown
Load
The E2E/E2E2’s short-circuit protection
function is valid if the polarity of the supply
voltage imposed is correct and within the
rated voltage range.
(Load
short-
Sensor
Incorrect
burn.
Load
Black
Brown
circuit)
Blue
(Load short-circuit)
Incorrect
Sensor
Blue
Wiring
DC 3-wire Models (NPN output)
Be sure to wire the E2E/E2E2 and load
correctly, otherwise it may explode or burn.
Load
Brown
Load
Brown
Sensor
Black
Sensor
Black
Blue
Incorrect
Incorrect
Blue
Connection with no load
DC 3-wire Models
AC 2-wire Models
Make sure to connect a proper load to the
E2E/E2E2 in operation, otherwise it may
explode or burn.
Load
Load
Brown
Brown
Sensor
Blue
Sensor
Blue
Incorrect
Incorrect
■ Precautions for Correct Use
Sensing Object
Metal Coating:
The sensing distances of the Proximity Sensor vary with the metal
coating on sensing objects.
Installation
Power Reset Time
The Proximity Sensor is ready to operate within 100 ms after power
is supplied. If power supplies are connected to the Proximity Sensor
and load respectively, be sure to supply power to the Proximity
Sensor before supplying power to the load.
Power OFF
The Proximity Sensor may output a pulse signal when it is turned
OFF. Therefore, it is recommended to turn OFF the load before
turning OFF the Proximity Sensor.
Power Supply Transformer
When using a DC power supply, make sure that the DC power
supply has an insulated transformer. Do not use a DC power supply
with an auto-transformer.
E2E/E2E2 Cylindrical Proximity Sensor
35