Mutual Interference
When installing two or more Sensors face to face or side by side, ensure that the minimum distances given in the following table are maintained.
B
A
Model
Shielded
Item
M8
M12
30 (20) mm
20 (12) mm
120 (60) mm
100 (50) mm
M18
50 (30) mm
35 (18) mm
200 (100) mm
110 (60) mm
M30
100 (50) mm
70 (35) mm
E2E-X@D@
A
B
A
B
20 mm
DC 2-wire
15 mm
80 mm
60 mm
E2E-X@T1
Unshielded
300 (100) mm
200 (100) mm
AC/DC 2-wire
E2E2-X@D@
DC 2-wire
E2E-X@E@
E2E-X@F@
DC 3-wire
Shielded
A
B
A
B
20 mm
15 mm
80 mm
60 mm
30 (20) mm
20 (12) mm
120 (60) mm
100 (50) mm
50 (30) mm
35 (18) mm
200 (100) mm
110 (60) mm
100 (50) mm
70 (35) mm
Unshielded
300 (100) mm
200 (100) mm
E2E-X@Y@
AC 2-wire
E2E2-X@B@
E2E2-X@C@
DC 3-wire
E2E2-X@Y@
AC 2-wire
Model
Shielded
Item
3 dia.
4 dia.
M5
5.4 dia.
E2E-X@B@
E2E-X@C@
E2E-C@B@
E2E-C@C@
DC 3-wire
A
B
20 mm
15 mm
Note: Values in parentheses apply to Sensors operating at different frequencies.
34
E2E/E2E2 Cylindrical Proximity Sensor