欢迎访问ic37.com |
会员登录 免费注册
发布采购

E2E-X10D1-M1G 参数 Datasheet PDF下载

E2E-X10D1-M1G图片预览
型号: E2E-X10D1-M1G
PDF下载: 下载PDF文件 查看货源
内容描述: 您搜索的接近传感器始于E2E世界领先的性能和质量 [Your Search for Proximity Sensors Starts with the World-leading Performance and Quality of the E2E]
分类和应用: 传感器接近传感器
文件页数/大小: 36 页 / 2870 K
品牌: OMRON [ OMRON ELECTRONICS LLC ]
 浏览型号E2E-X10D1-M1G的Datasheet PDF文件第12页浏览型号E2E-X10D1-M1G的Datasheet PDF文件第13页浏览型号E2E-X10D1-M1G的Datasheet PDF文件第14页浏览型号E2E-X10D1-M1G的Datasheet PDF文件第15页浏览型号E2E-X10D1-M1G的Datasheet PDF文件第17页浏览型号E2E-X10D1-M1G的Datasheet PDF文件第18页浏览型号E2E-X10D1-M1G的Datasheet PDF文件第19页浏览型号E2E-X10D1-M1G的Datasheet PDF文件第20页  
E2E
E2E-X@E@/F@ DC 3-Wire Models
Size
Shielded
Item
Model
Shielded
E2E
-X1R5E@/F@
1.5 mm
±10%
0 to 1.2 mm
M8
Unshielded
E2E
-X2ME@/F@
2 mm
±10%
0 to 1.6 mm
Shielded
E2E
-X2E@/F@
M12
Unshielded
E2E
-X5ME@/F@
5 mm
±10%
0 to 4 mm
Shielded
E2E
-X5E@/F@
M18
Unshielded
E2E
-X10ME@/F@
10 mm
±10%
0 to 8 mm
Shielded
E2E-X10E@/
F@
M30
Unshielded
E2E
-X18ME@/F@
18 mm
±10%
0 to 14 mm
Sensing distance
Set distance
Differential travel
Detectable object
Standard sensing
object
Response frequency
*1
Power supply voltage
(operating voltage
range)
*2
Current consumption
Control
output
Indicators
Operation mode
(with sensing object
approaching)
Protection circuits
Ambient
temperature range
*2
Ambient humidity
range
Temperature
influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Pre-
wired
Models
Connec-
tor
Models
Case
Sensing
surface
Materials
Clamp-
ing nuts
Toothed
washer
Accessories
Load
current
*2
Residual
voltage
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data
on pages 18 and 19.)
Iron,
8
×
8
×
1 mm
2 kHz
Iron, 12
×
12
×
1 mm
0.8 kHz
1.5 kHz
Iron,
15
×15 ×
1 mm
0.4 kHz
Iron,
Iron, 30
×
30
×
1 mm
18
×
18
×
1 mm
0.6 kHz
0.2 kHz
0.4 kHz
Iron,
54
×
54
×
1 mm
0.1 kHz
12 to 24 VDC (10 to 40 VDC), ripple (p-p): 10% max.
13 mA max.
200 mA max.
2 V max. (Load current: 200 mA, Cable length: 2 m)
Operation indicator (red)
E1/F1 Models: NO
E2/F2 Models: NC
Refer to the timing charts under
I/O Circuit Diagrams
on page 21 for details.
Load short-circuit protection, Surge suppressor, Reverse polarity protection
Operating/Storage:
−40
to 85°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±15%
max. of sensing distance at 23°C in the temperature range of
−40
to 85°C
±10%
max. of sensing distance at 23°C in the temperature range of
−25
to 70°C
±1%
max. of sensing distance at rated voltage in the rated voltage
±15%
range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
2
10 times each in X, Y, and
Z directions
Destruction: 1,000 m/s
2
10 times each in X, Y, and Z directions
Pre-wired Models : IEC 60529 IP67, in-house standards: oil-resistant
Connector Models : IEC 60529 IP67
Pre-wired Models (Standard cable length: 2 m) and Connector Models
Approx. 65 g
Approx. 75 g
Approx. 150 g
Approx. 195 g
Weight
Approx. 15 g
Stainless steel (SUS303)
PBT
Nickel-plated brass
Zinc-plated iron
Instruction manual
Approx. 25 g
Nickel-plated brass
Approx. 40 g
Approx. 90 g
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
*2. When using an M8 Model at an ambient temperature between 70 and 85°C, supply 10 to 30 VDC to the Sensor and make sure that the Sensor has a control output
of 100 mA maximum.