A165E  
Safety Precautions  
Be sure to read the precautions for all pushbutton switches in the Pushbutton Switches Group Catalog (Cat. No. X032).  
!CAUTION  
If the Operation Unit is separated from the Switch Unit, the  
equipment will not stop, creating a hazardous condition.  
Always confirm that safety functions are operating before  
starting operation.  
LEDs  
The LED current-limiting resistor is built-in, so external resistance is  
not required.  
Rated voltage  
24 VAC/VDC  
Internal limiting resistor  
2.4 kΩ  
Precautions for Correct Use  
Operating Torque  
Mounting  
Do not exceed an operating torque of 0.49 N·m in the direction of  
rotation.  
Always make sure that the power is turned OFF before mounting,  
removing, or wiring the Switch, or performing maintenance.  
Electrical shock or fire may result if the power is not turned OFF.  
The tightening torque is 0.29 to 0.49 N·m.  
Do not pull the operating button or apply excessive force to any  
side of the button.  
Otherwise it may be damaged.  
Wiring  
Others  
Be sure to use electrical wires that are a size appropriate for the  
applied voltage and carry current. Perform soldering according to  
the conditions given below. If the soldering is not properly  
performed, abnormal heating may result, possibly resulting in fire.  
1. Hand soldering: 30 W, within 5 s  
The oil-resistant IP65 uses NBR rubber and is resistant to general  
cutting oil and cooling oil. Some special oils cannot be used with  
the oil-resistant IP65, however, so contact your OMRON  
representative for details.  
If the panel is to be coated, make sure that the panel meets the  
specified dimensions after coating.  
Due to the structure of the Switch, severe shock or vibration may  
cause malfunctions or damage to the Switch.  
Also, most Switches are made from resin and will be damaged if  
they come into contact with sharp objects. Particularly scratches  
on the Operation Unit may create visual and operational obtrusions.  
Handle the Switches with care, and do not throw or drop them.  
2. Dip soldering: 240°C, within 3 s  
Wait for one minute after soldering before exerting any external  
force on the solder.  
Use non-corrosive resin fluid as the flux.  
Make sure that the electric cord is wired so that it does not touch  
the Unit. If the electric cord will touch the Unit, then electric wires  
with a heat resistance of 100°C min. must be used.  
After wiring the Switch, maintain an appropriate clearance and  
creepage distance.  
Operating Environment  
The IP65 model is designed with a degree of protection so that it  
will not sustain damage if it is subjected to water from any direction  
to the front of the panel.  
The Switch is intended for indoor use only. Using the Switch  
outdoor may cause it to fail.  
Do not allow the  
Switch to drop and hit  
the floor.  
Using the Microload  
Insert a contact protection circuit, if necessary, to prevent the  
reduction of life expectancy due to extreme wear on the contacts  
caused by loads where inrush current occurs when the contact is  
opened and closed.  
The A165E-@U (one-piece construction) allows both a standard  
load (125 V at 1 A, 250 V at 0.5 A) and a microload. If a standard  
load is applied, however, the microload area cannot be used. If the  
microload area is used with a standard load, the contact surface  
will become rough, and the opening and closing of the contact for  
a microload may become unreliable.  
Do not place or drop  
heavy objects on the  
Switch.  
The minimum applicable load is the N-level reference value. This  
value indicates the malfunction reference level for the reliability  
level of 60% (λ 60) (conforming to JIS C5003).  
The equation, λ 60 = 0.5 x 106/time indicates that the estimated  
malfunction rate is less than 1/2,000,000 with a reliability level of  
60%.  
Do not operate the  
Switch with hard or  
sharp objects.  
Hammer  
Screwdriver  
0.15 mA  
Area of use  
Invalid  
area  
1 mA  
Current (mA)  
9