A165E  
Safety Precautions  
Be sure to read the precautions for all A165E models in the website at: http://www.ia.omron.com/.  
Indication and Meaning for Safe Use  
Using the Microload  
Insert a contact protection circuit, if necessary, to prevent the  
reduction of life expectancy due to extreme wear on the contacts  
caused by loads where inrush current occurs when the contact is  
opened and closed.  
Indicates a potentially hazardous situation  
which, if not avoided, may result in minor  
or moderate injury or in property damage.  
CAUTION  
The A165E-@U (one-piece construction) allows both a standard  
load (125 V at 1 A, 250 V at 0.5 A) and a microload. If a standard  
load is applied, however, the microload area cannot be used. If the  
microload area is used with a standard load, the contact surface  
will become rough, and the opening and closing of the contact for  
a microload may become unreliable.  
Precautions  
for Safe Use  
Supplementary comments on what to do  
or avoid doing, to use the product safely.  
!CAUTION  
If the Operation Unit is separated from the Switch Unit, the  
equipment will not stop, creating a hazardous condition.  
Always confirm that safety functions are operating before  
starting operation.  
The minimum applicable load is the N-level reference value. This  
value indicates the malfunction reference level for the reliability  
level of 60% (λ 60) (conforming to JIS C5003).  
The equation, λ 60 = 0.5 x 106/time indicates that the estimated  
malfunction rate is less than 1/2,000,000 with a reliability level of  
60%.  
Precautions for Correct Use  
Mounting  
0.15 mA  
Always make sure that the power is turned OFF before mounting,  
removing, or wiring the Switch, or performing maintenance.  
Electrical shock or fire may result if the power is not turned OFF.  
The tightening torque is 0.29 to 0.49 N·m.  
Area of use  
Wiring  
Be sure to use electrical wires that are a size appropriate for the  
applied voltage and carry current. Perform soldering according to  
the conditions given below. If the soldering is not properly  
performed, abnormal heating may result, possibly resulting in fire.  
1. Hand soldering: 30 W, within 5 s  
Invalid  
area  
1 mA  
2. Dip soldering: 240°C, within 3 s  
Current (mA)  
Wait for one minute after soldering before exerting any external  
force on the solder.  
Use non-corrosive resin fluid as the flux.  
Make sure that the electric cord is wired so that it does not touch  
the Unit. If the electric cord will touch the Unit, then electric wires  
with a heat resistance of 100°C min. must be used.  
After wiring the Switch, maintain an appropriate clearance and  
creepage distance.  
LEDs  
The LED current-limiting resistor is built-in, so external resistance is  
not required.  
Rated voltage  
24 VAC/VDC  
Internal limiting resistor  
2.4 kΩ  
Operating Torque  
Do not exceed an operating torque of 0.49 N·m in the direction of  
rotation.  
Do not pull the operating button or apply excessive force to any  
side of the button.  
Otherwise it may be damaged.  
Operating Environment  
The IP65 model is designed with a degree of protection so that it  
will not sustain damage if it is subjected to water from any direction  
to the front of the panel.  
The Switch is intended for indoor use only. Using the Switch  
outdoor may cause it to fail.  