Preparing for Operation  
Chapter 4  
Acceleration Time  
n20  
Setting range 0.0 to 999  
Factory setting 10.0 (seconds)  
(seconds)  
Deceleration time  
n21  
Setting range 0.0 to 999  
Factory setting 10.0 (seconds)  
(seconds)  
These constants are used to set acceleration time (required to increase the output fre-  
quency from the stopped state to the maximum frequency) and deceleration time (re-  
quired to decrease the output frequency from the maximum frequency to the stopped  
state).  
(Set the maximum frequency in n24.)  
The unit of setting is as follows:  
0.0 to 99.9 (seconds): 0.1 (second)  
100 to 999 (seconds): 1 (second)  
Acceleration and deceleration times can be changed even during operation. If, for ex-  
ample, acceleration time is to changed, light the ACC indicator with the Mode Key first,  
press the Increment or Decrement Key to change the value, then press the Enter Key.  
Deceleration time can be also changed in the same way. (Light the DEC indicator be-  
fore changing the deceleration time.)  
These constant settings are always valid regardless of whether the Inverter is oper-  
ated with the Digital Operator or control input.  
Explanation of n20 and n21 Settings  
Output frequency  
DC braking  
(50% of Inverter  
rated current)  
Maximum frequency  
0.5 second  
Time  
Acceleration time  
Deceleration time  