Preparing for Operation  
Chapter 4  
Forward/Reverse Rotation Selection  
n04  
Setting range  
Factory setting  
f%r, reU  
f%r  
(forward rota-  
tion)  
This constant is used to specify the direction of motor rotation when the Inverter is oper-  
ated with the Digital Operator.  
Value  
Description  
Forward rotation  
Reverse rotation  
f%r  
reU  
Note 1. While the Inverter is being operated with the Digital Operator, the direction of  
motor rotation can be changed by lighting the F/R indicator with the Mode Key  
first, pressing the Increment or Decrement Key to change the setting, then  
pressing the Enter Key.  
Note 2. The direction (forward/reverse) of motor rotation depends on the motor model  
used. Refer to the instruction manual for the motor.  
Multi-Function Input Selection  
n06  
Setting range 0 to 4  
Factory setting 1  
One of the following values can be selected for the multi-function input (S1) function:  
Value  
Description  
0
1
2
3
4
Forward/reverse rotation command (3-wire sequence)  
Fault reset (fault reset when ON)  
External fault (contact a: external fault when ON)  
External fault (contact b: external fault when OFF)  
Multi-step speed command (frequency reference 2 when ON)  
Multi-Function Output Selection  
n09  
Setting range 0, 1, 2  
Factory setting 1  
One of the following three values can be specified for the multi-function contact output  
(MA and MB) function. When the Inverter enters the state corresponding to the specified  
value, MA is turned on and MB is turned off.  
Value  
Description  
0
1
2
Fault occurrence  
Operation in progress (frequency reference is being output)  
Frequency matching (see note)  