 浏览型号3G3EV-AB004-CUE的Datasheet PDF文件第38页浏览型号3G3EV-AB004-CUE的Datasheet PDF文件第39页浏览型号3G3EV-AB004-CUE的Datasheet PDF文件第40页浏览型号3G3EV-AB004-CUE的Datasheet PDF文件第41页浏览型号3G3EV-AB004-CUE的Datasheet PDF文件第43页浏览型号3G3EV-AB004-CUE的Datasheet PDF文件第44页浏览型号3G3EV-AB004-CUE的Datasheet PDF文件第45页浏览型号3G3EV-AB004-CUE的Datasheet PDF文件第46页  
Specifications  
Chapter 4  
H Control Characteristics  
Control method  
Sine-wave PWM method (automatic torque boost)  
Frequency control range  
0.5 to 400 Hz (standard model: 1.5 to 400 Hz)  
Frequency accuracy  
(temperature fluctuation)  
Digital command:  
0.01% (–10°C to 50°C)  
Analog command:  
1% (25 10°C)  
Frequency setting  
resolution  
Digital command:  
0.1 Hz (less than 100 Hz), 1 Hz (100 Hz or more)  
Analog command:  
0.06 Hz (60 Hz)  
Frequency output resolution 0.1 Hz (operation resolution)  
Overload resistance  
1 minute or less when 150% of rated output current is received  
Frequency setting signal  
0 to 10 VDC (20 k) or 4 to 20 mA (250 )  
Note This setting can be switched using the internal DIP switch.  
Acceleration/Deceleration  
time  
0.0 to 999 seconds (acceleration and deceleration times are set separately)  
Braking torque (continuous Approximately 20%  
regenerative braking)  
Note 125% to 220% when braking resistor is externally installed.  
Voltage/Frequency  
characteristics  
Simple V/f pattern setting  
H Protection Functions  
Motor protection  
Electronic thermal protection  
Instantaneous overcurrent  
protection  
When 250% of the rated output amperage is exceeded  
Overload protection  
When 150% of the rated output amperage is exceeded for one minute  
Overvoltage protection  
Stops the system when DC voltage of the main circuit exceeds  
approximately 410 V (400-VAC class: 820 V)  
Voltage drop protection  
3G3EV-A2j: Stops the system when voltage drops below approximately  
200 VDC  
3G3EV-ABj: Stops the system when voltage drops below approximately  
160 VDC  
3G3EV-A4j: Stops the system when voltage drops below approximately  
400 VDC  
Protection from  
instantaneous power  
interruption  
Stops the system when a power interruption lasts for 15 ms or more.  
Operation can be continued by setting constant No. 36 as follows:  
Operation is continued if a power interruption only lasts for approximately 0.5  
second or less.  
Operation is continued unconditionally.  
Detects a fin temperature of 110 10°C  
Radiation fin overheat  
protection  
Ground protection  
Overcurrent level protection  
4-4  