PEDD514260ESL-01
MSM514260E/ESL
DC Characteristics
(VCC = 5V ± 10%, Ta = 0°C to 70°C)
MSM514260 MSM514260
E/ESL-60
E/ESL-70
Max
Min.
Symbol
Parameter
Condition
Unit Note
Max
Min.
V
I
= −5.0mA
Output High Voltage
Output Low Voltage
2.4
0
VCC
0.4
2.4
0
VCC
0.4
V
V
OH
OH
V
I
OL
= 4.2mA
OL
0V ≤ V ≤ V +0.5V;
I
CC
I
Input Leakage Current
Output Leakage Current
10
10
−10
−10
−10
−10
µA
µA
All other pins not
under test = 0V
LI
DQ disable
I
LO
10
10
0V ≤ V ≤ V
O
CC
RAS, CAS cycling,
= Min.
Average Power Supply Current
(Operating)
I
115
105
mA
1,2
CC1
t
RC
RAS, CAS = V
RAS, CAS ≥
2
1
2
1
IH
mA
1
Power Supply Current
(Standby)
I
CC2
V
CC
– 0.2V
200
200
1,5
µA
RAS cycling,
Average Power Supply Current
I
115
105
mA
1,2
CAS = V ,
CC3
IH
(RAS-only Refresh)
t
= Min.
RC
RAS = V ,
IH
Power Supply Current
(Standby)
I
5
5
mA
mA
mA
1
CAS = V ,
CC5
IL
DQ = enable
Average Power Supply Current
RAS = cycling,
CAS before RAS
I
115
115
105
105
1,2
1,3
CC6
(CAS before RAS Refresh)
RAS = V ,
IL
Average Power Supply Current
(Fast Page Mode)
I
CAS cycling,
CC7
t
= Min.
PC
t
= 125µs
RC
Average Power Supply Current
(Battery Backup)
1,4,
5
I
300
300
300
300
µA
µA
CAS before RAS
= 1µs
CC10
t
RAS
Average Power Supply Current
(CAS before RAS Self-Refresh)
RAS ≤ 0.2V,
CAS ≤ 0.2V,
I
1,5
CCS
Notes: 1. ICC Max. is specified as ICC for output open condition.
2. The address can be changed once or less while RAS = VIL.
3. The address can be changed once or less while CAS = VIH.
4. VCC − 0.2V ≤ VIH ≤ VCC + 0.5V, − 0.5V ≤ VIL ≤ 0.2V.
5. SL version.
5/14