欢迎访问ic37.com |
会员登录 免费注册
发布采购

ML87V21071TB 参数 Datasheet PDF下载

ML87V21071TB图片预览
型号: ML87V21071TB
PDF下载: 下载PDF文件 查看货源
内容描述: [Consumer Circuit, PQFP100, 14 X 14 MM, 0.50 MM PITCH, PLASTIC, TQFP-100]
分类和应用: 商用集成电路
文件页数/大小: 123 页 / 812 K
品牌: OKI [ OKI ELECTRONIC COMPONETS ]
 浏览型号ML87V21071TB的Datasheet PDF文件第84页浏览型号ML87V21071TB的Datasheet PDF文件第85页浏览型号ML87V21071TB的Datasheet PDF文件第86页浏览型号ML87V21071TB的Datasheet PDF文件第87页浏览型号ML87V21071TB的Datasheet PDF文件第89页浏览型号ML87V21071TB的Datasheet PDF文件第90页浏览型号ML87V21071TB的Datasheet PDF文件第91页浏览型号ML87V21071TB的Datasheet PDF文件第92页  
PEDL87V21071-01  
OKI Semiconductor  
ML87V21071  
2.3.3 Noise Reduction Motion Compensation Mode/Noise Detection Inclination Setting  
SUB_ADDRESS = 4Ah(W/R): Luminance noise reduction motion compensation mode/Noise detection  
inclination setting  
DATA_BIT  
BIT7  
BIT6  
BIT5  
BIT4  
BIT3  
BIT2  
BIT1  
BIT0  
YSLT  
Register name  
AYABN  
YABN  
YFAM  
YNRM  
3
2
1
0
SUB_ADDRESS = 4Bh(W/R): Chrominance noise reduction motion compensation mode/Noise detection  
inclination setting  
DATA_BIT  
BIT7  
BIT6  
BIT5  
BIT4  
BIT3  
BIT2  
BIT1  
BIT0  
CSLT  
Register name  
ACABN  
CABN  
CFAM  
CNRM  
3
2
1
0
YNRM Initial value: 0; Setting range: Refer to Table R2-3-3 (1).  
Sets luminance noise reduction motion compensation mode selection.  
YFAM Initial value: 0; Setting range: Refer to Table R2-3-3 (3).  
Sets luminance adaptive noise reduction mode.  
YABN Initial value: 0; Setting range: Refer to Table R2-3-3 (5).  
Sets luminance absolute noise mode.  
It is possible not to perform 1/2 motion compensation as absolute noise with respect to the motion level  
detection noise of luminance signal.  
AYABN Initial value: 0; Setting range: Refer to Table R2-3-3 (7).  
Sets auto mode luminance absolute noise mode.  
By setting to “1”, the luminance absolute noise mode operates in luminance noise follow-up state  
(YDTO2 = 1) of the auto mode. (The same operation as YABN = 1.)  
YSLT[3:0] Initial value: 0001; Setting range: Refer to Table R2-3-3 (9).  
Sets luminance noise reduction noise detection lines/convergence lines inclination.  
CNRM Initial value: 0; Setting range: Refer to Table R2-3-3 (2).  
Sets chrominance noise reduction motion compensation mode selection.  
CFAM Initial value: 0; Setting range: Refer to Table R2-3-3 (4).  
Sets chrominance adaptive noise reduction mode.  
CABN Initial value: 0; Setting range: Refer to Table R2-3-3 (6).  
Sets chrominance absolute noise mode.  
It is possible not to perform 1/2 motion compensation as absolute noise with respect to the motion level  
detection noise of chrominance signal.  
ACABN Initial value: 0; Setting range: Refer to Table R2-3-3 (8).  
Sets auto mode chrominance absolute noise mode.  
By setting to “1”, the chrominance absolute noise mode operates in the chrominance noise follow-up  
state (CDTO2 = 1) of the auto mode. (The same operation as CABN = 1.)  
CSLT[3:0] Initial value: 0001; Setting range: Refer to Table R2-3-3 (10).  
Sets chrominance noise reduction noise detection line/convergence line inclination.  
88/123  
 复制成功!