欢迎访问ic37.com |
会员登录 免费注册
发布采购

ML7012-03GA 参数 Datasheet PDF下载

ML7012-03GA图片预览
型号: ML7012-03GA
PDF下载: 下载PDF文件 查看货源
内容描述: [Modem, 2.4kbps Data, PQFP64, 14 X 14 MM, 0.80 MM PITCH, PLASTIC, QFP-64]
分类和应用: 电信电信集成电路
文件页数/大小: 22 页 / 124 K
品牌: OKI [ OKI ELECTRONIC COMPONETS ]
 浏览型号ML7012-03GA的Datasheet PDF文件第7页浏览型号ML7012-03GA的Datasheet PDF文件第8页浏览型号ML7012-03GA的Datasheet PDF文件第9页浏览型号ML7012-03GA的Datasheet PDF文件第10页浏览型号ML7012-03GA的Datasheet PDF文件第12页浏览型号ML7012-03GA的Datasheet PDF文件第13页浏览型号ML7012-03GA的Datasheet PDF文件第14页浏览型号ML7012-03GA的Datasheet PDF文件第15页  
FEDL 7012-03-01  
1
Semiconductor  
ML7012-03  
(3) AT command list  
It is regarded that n = 0 when the parameter is not specified to the command with parameter (n).  
CMD  
Style  
Function  
Goes to on-line command mode from data mode.  
Inputs +++AT <CR> in data mode.  
Does not move to on-line command mode until <CR>is  
input.  
Initial Value  
Note  
+++AT  
<CR>  
A
ATA  
ATD  
Starts line connection in answer mode  
Starts line connection in originate mode  
Connects lines in originate mode after dialing.  
c: Dial control character  
Pulse: 0, 1, 2, 3 ,4, 5, 6, 7, 8, 9  
Tone: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C, D, *, #  
@ Silence Detection  
Next dialing is executed when continuous silence of 5 sec is  
detected after ring back tone within the period specified in S7  
register.  
Sends back ‘BUSY’ when busy tone is detected and sends  
back ‘NO ANSWER’ when no silence is detected after ring  
back tone.  
! Flash  
Dialing is put on hold for the period specified in the S8  
register for pause settings.  
D
ATDc  
,Comma  
The line is put on-hook for 0.5 sec.  
Dialing is put on hold for the period specified in the S8  
register for pause settings.  
; Moves to command mode without disconnecting lines after  
dialing is completed.  
P: Dials the number in pulse mode thereafter.  
T: Dials the number in tone mode thereafter.  
W: Detects a dial tone.  
Detects the next dial string process when dial tone is  
detected during the period specified in S7 register  
regardless of ATXn command settings.  
When it is not detected, ‘NO DIALTONE’ is returned.  
Selects the answer-back function for the commands.  
N = 0: No answer back for command input characters.  
N = 1: Answer back for command input characters.  
Controls the line connection.  
E
ATEn  
1
H
I
ATH  
ATI  
N = 0: On-hook  
N = 1: Off-hook  
Displays the modem manufacturer’s code  
Selects the monitor speaker operation.  
N = 0: Always OFF  
M
O
ATMn  
ATO  
N = 1: ON from dialing to line connection  
N = 2: Always ON  
N = 3: ON when connected with a remote modem  
1
Goes to data mode from on-line command mode.  
11/22