PEDL60851C-02  
1
Semiconductor  
ML60851C  
EP1 Transmit Packet Ready Bit (D5)  
This bit can be read by the local MCU. Further, this bit can be set to “1” by writing “1” to the D5 bit.  
The conditions of asserting and deasserting this bit are the following. EP1 has a two-layer FIFO, and even the  
packet ready bits are present independently for layer A and layer B. The switching between these two layers is  
performed automatically by the ML60851C.  
Bit name  
Asserting condition  
Action when asserted  
EP1 Transmit packet ready (D5) When the local MCU has set the bits Data transmission is possible from  
of both layer A and layer B.  
EP1 when the bit for at least one of  
layer A and layer B has been  
asserted.  
Bit name  
Deasserting condition  
Action when deasserted  
EP1 Transmit packet ready (D5) When an ACK is received from the  
EP1 is locked when both layer A and  
layer B have not prepared the  
transmit data.  
host computer for the data  
transmission from either layer A or  
layer B.  
See the explanation of the operation of the two-layer FIFO given in the Section on ‘Functional Description’.  
EP2 Transmit Packet Ready Bit (D6)  
This bit can be read by the local MCU. Further, this bit can be set to “1” by writing “1” to the D6 bit.  
The conditions of asserting and negating this bit are the following.  
Bit name  
Asserting condition  
Action when asserted  
EP2 Transmit packet ready (D6) When the local MCU has set this bit. Data transmission is possible from  
EP2.  
Bit name  
Deasserting condition  
Action when deasserted  
EP2 is locked.  
EP2 Transmit packet ready (D6) When an ACK is received from the  
host computer in response to the  
data transmission from EP2.  
EP3 Transmit Packet Ready Bit (D7)  
This bit can be read by the local MCU. Further, this bit can be set to “1” by writing “1” to the D7 bit.  
The conditions of asserting and deasserting this bit are the following.  
Bit name  
Asserting condition  
Action when asserted  
EP3 Transmit packet ready (D7) When the local MCU has set this bit. Data transmission is possible from  
EP3.  
Bit name  
Deasserting condition  
Action when deasserted  
EP3 is locked.  
EP2 Transmit packet ready (D7) When an ACK is received from the  
host computer in response to the  
data transmission from EP3.  
18/67  