FEDL2500BFULL-02
OKI Semiconductor
ML2500BTA
3. Timing for Pausing Operation by the PAUSE Command
The following charts show timings for pausing recording operation by using the PAUSE command at 6.4 kHz
sampling frequency.
PAUSE command input
PAUSE command input
CS(I)
MON(O)
RPM
Bit(O)
tSPCP1
tPSCP
VPM
Bit(O)
Pausing
Recording
Status Recording
PAUSE command input
STOP command input
tSPCM
CS(I)
MON(O)
tSPCR
RPM
Bit(O)
tPSCP
tSPCP2
VPM
Bit(O)
200 ms (Typ.)
62.5 ms (Typ.)
Pausing
Status
Recording
Command Wait
Recording
Dummy Recording
(NOTE) If the STOP command is input while recording is suspended by the PAUSE command, the LSI resumes
recording and keeps on recording until the last address of the current page is reached. This “lag” recording time is
about 62.5 ms (Typ.).
Afterwards, dummy recording is taken place up to the end of the following sector (max. 2 sectors). This dummy
recording takes about 200 ms (Typ.).
The dummy recording is given in the device specification and the recording contents are undefined.
12/27