1.4 Phrase 2 Recording Operation  
(1)  
(2)  
Keep on inputting “H” level to the REC2 pin to power up and start recording from the top  
address of the memory. Recording goes on while the REC2 pin being held “H” level.  
The LSI automatically ends recording when the last address of the memory has been  
reached.  
(3)  
(4)  
The LSI automatically shifts to low-power consumption mode after recording ends.  
To stop recording for Phrase 2 before reaching the last address, bring the REC2 pin down  
to “L” level. The LSI automatically shifts to low-power consumption mode after recording  
stops.  
(5)  
During recording operation any signal input to other pins than the REC2 is disregarded.  
Note: Re-recording always causes to overwrite the existing recording data for a given phrase.  
Start  
Invalid Input  
Stop  
REC1  
REC2  
MON  
Power Down  
Powering Up  
Recording  
Powering Down  
Power Down  
Status  
Stopping Process  
Figure 1.4 Timing Chart for Phrase 2 Recording Operation  
1.5 Phrase 2 Playback Operation  
(1)  
(2)  
Input a “H” pulse to the PLAY2 pin to power up and start playback from the center address of  
the memory.  
The LSI automatically ends playback when the last address of the recorded phrase has been  
reached.  
(3)  
(4)  
The LSI automatically shifts to low-power consumption mode after playback ends.  
To stop playback of Phrase 2 before reaching its last address, input a “H” pulse again to the  
PLAY1 or PLAY2 pin. This will cause the LSI to stop playback and then automatically shift  
to low-power consumption mode.  
(5)  
During playback operation signal input to the PLAY1 or PLAY2 pin only is valid, any other  
signal input is disregarded  
Start Pulse  
Stop Pulse  
PLAY1  
PLAY2  
Stop  
MON  
Status Power Down  
Powering Up  
Playing Back  
Powering Down  
Power Down  
Figure 1.5 Timing Chart for Phrase 2 Playback Operation  