 浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第41页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第42页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第43页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第44页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第46页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第47页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第48页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第49页  
M58LT128HST, M58LT128HSB  
Read modes  
7.2  
Synchronous Burst Read mode  
In Synchronous Burst Read mode the data is output in bursts synchronized with the clock. It  
is possible to perform Burst reads across bank boundaries.  
Synchronous Burst Read mode can only be used to read the memory array. For other Read  
operations, such as Read Status Register, Read CFI and Read Electronic Signature, then  
Single Synchronous Read or Asynchronous Random Access Read must be used.  
In Synchronous Burst Read mode the flow of the data output depends on parameters that  
are configured in the Configuration Register.  
A burst sequence starts at the first clock edge (rising or falling depending on Valid Clock  
Edge bit CR6 in the Configuration Register) after the falling edge of Latch Enable or Chip  
Enable, whichever occurs last. Addresses are internally incremented and data is output on  
each data cycle after a delay, which depends on the X-latency bits CR13-CR11 of the  
Configuration Register.  
The number of words to be output during a Synchronous Burst Read operation can be  
configured as 4 words, 8 words, 16 words or Continuous (Burst Length bits CR2-CR0). The  
data can be configured to remain valid for one or two clock cycles (Data Output  
Configuration bit CR9).  
The order of the data output can be modified through the Wrap Burst bit in the Configuration  
Register. The burst sequence is sequential and can be confined inside the 4-, 8- or 16-word  
boundary (wrap) or overcome the boundary (no wrap).  
The WAIT signal may be asserted to indicate to the system that an output delay occurs. This  
delay depends on the starting address of the burst sequence and on the burst configuration.  
WAIT is asserted during the X-latency, the WAIT state, and at the end of a 4-, 8- and 16-  
word burst. It is only de-asserted when output data is valid. In Continuous Burst Read mode  
a WAIT state occurs when crossing the first 16-word boundary. If the starting address is  
aligned to the burst length (4-, 8- or 16-words), the wrapped configuration has no impact on  
the output sequence.  
The WAIT signal can be configured to be active Low or active High by setting CR10 in the  
Configuration Register.  
See Table 23: Synchronous Read AC characteristics and Figure 11: Synchronous Burst  
Read AC waveforms for details.  