 浏览型号M29W320ET70ZE1的Datasheet PDF文件第25页浏览型号M29W320ET70ZE1的Datasheet PDF文件第26页浏览型号M29W320ET70ZE1的Datasheet PDF文件第27页浏览型号M29W320ET70ZE1的Datasheet PDF文件第28页浏览型号M29W320ET70ZE1的Datasheet PDF文件第30页浏览型号M29W320ET70ZE1的Datasheet PDF文件第31页浏览型号M29W320ET70ZE1的Datasheet PDF文件第32页浏览型号M29W320ET70ZE1的Datasheet PDF文件第33页  
M29W320ET, M29W320EB  
Status register  
5
Status register  
The M29W320E has one Status register. It provides information on the current or previous  
Program or Erase operations. The various bits convey information and errors on the  
operation. Bus Read operations from any address, always read the Status register during  
Program and Erase operations. It is also read during Erase Suspend when an address  
within a block being erased is accessed.  
The bits in the Status register are summarized in Table 7: Status register bits.  
5.1  
Data Polling bit (DQ7)  
The Data Polling bit can be used to identify whether the Program/Erase Controller has  
successfully completed its operation or if it has responded to an Erase Suspend. The Data  
Polling bit is output on DQ7 when the Status register is read.  
During Program operations the Data Polling bit outputs the complement of the bit being  
programmed to DQ7. After successful completion of the Program operation the memory  
returns to Read mode and Bus Read operations from the address just programmed output  
DQ7, not its complement.  
During Erase operations the Data Polling bit outputs ’0’, the complement of the erased state  
of DQ7. After successful completion of the Erase operation the memory returns to Read  
mode.  
In Erase Suspend mode the Data Polling bit will output a ’1’ during a Bus Read operation  
within a block being erased. The Data Polling bit will change from a ’0’ to a ’1’ when the  
Program/Erase Controller has suspended the Erase operation.  
Figure 6: Data Polling flowchart, gives an example of how to use the Data Polling bit. A Valid  
Address is the address being programmed or an address within the block being erased.  
5.2  
Toggle bit (DQ6)  
The Toggle bit can be used to identify whether the Program/Erase Controller has  
successfully completed its operation or if it has responded to an Erase Suspend. The Toggle  
bit is output on DQ6 when the Status register is read.  
During Program and Erase operations the Toggle bit changes from ’0’ to ’1’ to ’0’, etc., with  
successive Bus Read operations at any address. After successful completion of the  
operation the memory returns to Read mode.  
During Erase Suspend mode the Toggle bit will output when addressing a cell within a block  
being erased. The Toggle bit will stop toggling when the Program/Erase Controller has  
suspended the Erase operation.  
Figure 7: Toggle flowchart, gives an example of how to use the Data Toggle bit. Figure 13  
and Figure 14 describe Toggle bit timing waveform.  