欢迎访问ic37.com |
会员登录 免费注册
发布采购

M29W320ET70ZE1 参数 Datasheet PDF下载

M29W320ET70ZE1图片预览
型号: M29W320ET70ZE1
PDF下载: 下载PDF文件 查看货源
内容描述: 32兆位( 4Mbx8或2Mbx16 ,统一参数块,引导块) 3V供应闪存 [32 Mbit (4Mbx8 or 2Mbx16, Uniform Parameter Blocks, Boot Block) 3V supply Flash memory]
分类和应用: 闪存
文件页数/大小: 63 页 / 1191 K
品牌: NUMONYX [ NUMONYX B.V ]
 浏览型号M29W320ET70ZE1的Datasheet PDF文件第17页浏览型号M29W320ET70ZE1的Datasheet PDF文件第18页浏览型号M29W320ET70ZE1的Datasheet PDF文件第19页浏览型号M29W320ET70ZE1的Datasheet PDF文件第20页浏览型号M29W320ET70ZE1的Datasheet PDF文件第22页浏览型号M29W320ET70ZE1的Datasheet PDF文件第23页浏览型号M29W320ET70ZE1的Datasheet PDF文件第24页浏览型号M29W320ET70ZE1的Datasheet PDF文件第25页  
M29W320ET, M29W320EB  
Command interface  
4.3  
Read CFI Query command  
The Read CFI Query Command is used to read data from the Common Flash Interface  
(CFI) memory Area. This command is valid when the device is in the Read Array mode, or  
when the device is in Auto Select mode.  
One Bus Write cycle is required to issue the Read CFI Query Command. Once the  
command is issued subsequent Bus Read operations read from the Common Flash  
Interface memory Area.  
The Read/Reset command must be issued to return the device to the previous mode (the  
Read Array mode or Auto Select mode). A second Read/Reset command would be needed  
if the device is to be put in the Read Array mode from Auto Select mode.  
See Appendix B: Common Flash Interface (CFI), Table 22, Table 23, Table 24, Table 25,  
Table 26 and Table 27 for details on the information contained in the Common Flash  
Interface (CFI) memory area.  
4.4  
Program command  
The Program command can be used to program a value to one address in the memory array  
at a time. The command requires four Bus Write operations, the final write operation latches  
the address and data, and starts the Program/Erase Controller.  
If the address falls in a protected block then the Program command is ignored, the data  
remains unchanged. The Status register is never read and no error condition is given.  
During the program operation the memory will ignore all commands. It is not possible to  
issue any command to abort or pause the operation. After programming has started, Bus  
Read operations output the Status register content. See Section 5: Status register for more  
details. Typical program times are given in Table 6  
After the program operation has completed the memory will return to the Read mode, unless  
an error has occurred. When an error occurs Bus Read operations will continue to output  
the Status register. A Read/Reset command must be issued to reset the error condition and  
return to Read mode.  
Note that the Program command cannot change a bit set at ’0’ back to ’1’. One of the Erase  
Commands must be used to set all the bits in a block or in the whole memory from ’0’ to ’1’.  
21/63  
 复制成功!