 浏览型号M25PE16-VMW6TG的Datasheet PDF文件第20页浏览型号M25PE16-VMW6TG的Datasheet PDF文件第21页浏览型号M25PE16-VMW6TG的Datasheet PDF文件第22页浏览型号M25PE16-VMW6TG的Datasheet PDF文件第23页浏览型号M25PE16-VMW6TG的Datasheet PDF文件第25页浏览型号M25PE16-VMW6TG的Datasheet PDF文件第26页浏览型号M25PE16-VMW6TG的Datasheet PDF文件第27页浏览型号M25PE16-VMW6TG的Datasheet PDF文件第28页  
Instructions  
M25PE16  
6.3  
Read identification (RDID)  
The read identification (RDID) instruction allows to read the device identification data:  
Manufacturer identification (1 byte)  
Device identification (2 bytes)  
A unique ID code (UID) (17 bytes, of which 16 available upon customer request)  
The manufacturer identification is assigned by JEDEC, and has the value 20h for Numonyx.  
The device identification is assigned by the device manufacturer, and indicates the memory  
type in the first byte (80h), and the memory capacity of the device in the second byte (15h).  
The UID contains the length of the following data in the first byte (set to 10h), and 16 bytes  
of the optional customized factory data (CFD) content. The CFD bytes are read-only and  
can be programmed with customers data upon their demand. If the customers do not make  
requests, the device is shipped with all the CFD bytes programmed to zero (00h).  
Any read identification (RDID) instruction while an erase or program cycle is in progress, is  
not decoded, and has no effect on the cycle that is in progress.  
The device is first selected by driving Chip Select (S) Low. Then, the 8-bit instruction code  
for the instruction is shifted in. After this, the 24-bit device identification, stored in the  
memory, the 8-bit CFD length followed by 16 bytes of CFD content will be shifted out on  
serial data output (Q). Each bit is shifted out during the falling edge of Serial Clock (C).  
The instruction sequence is shown in Figure 8.  
The read identification (RDID) instruction is terminated by driving Chip Select (S) High at  
any time during data output.  
When Chip Select (S) is driven High, the device is put in the standby power mode. Once in  
the standby power mode, the device waits to be selected, so that it can receive, decode and  
execute instructions.  
Table 6.  
Read identification (RDID) data-out sequence  
Device identification  
UID  
Manufacturer  
identification  
Memory type  
80h  
Memory capacity  
CFD length  
CFD content  
20h  
15h  
10h  
16 bytes  
Figure 8.  
Read identification (RDID) instruction sequence and data-out sequence  
S
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15  
16 17 18  
28 29 30 31  
C
D
Instruction  
Manufacturer identification  
Device identification  
UID  
High Impedance  
Q
15 14 13  
MSB  
3
2
1
0
MSB  
MSB  
AI06809c  
24/58