M25P10-A
Table 17.
Instruction times (device grade 3)
(1)
DC and AC parameters
Test conditions specified in
and
Symbol
t
W
t
PP(4)
t
SE
t
BE
2. At 85 °C.
3. Preliminary data.
4. When using the Page Program (PP) instruction to program consecutive bytes, optimized timings are
obtained with one sequence including all the bytes versus several sequences of only a few bytes. (1
≤
n
≤
256).
Alt.
Parameter
Write Status Register cycle time
Page Program cycle time (256 bytes)
Page Program cycle time (n bytes)
Sector Erase cycle time
Bulk Erase cycle time
Min
Typ
(2)(3)
8
1.5
0.4+
n*1.1/256
1
4.5
Max
(3)
15
Unit
ms
5
ms
3
10
s
s
1. Only for products with process technology code X.
39/51