 浏览型号LP3971SQX-B410的Datasheet PDF文件第12页浏览型号LP3971SQX-B410的Datasheet PDF文件第13页浏览型号LP3971SQX-B410的Datasheet PDF文件第14页浏览型号LP3971SQX-B410的Datasheet PDF文件第15页浏览型号LP3971SQX-B410的Datasheet PDF文件第17页浏览型号LP3971SQX-B410的Datasheet PDF文件第18页浏览型号LP3971SQX-B410的Datasheet PDF文件第19页浏览型号LP3971SQX-B410的Datasheet PDF文件第20页  
VIN, MIN = ILOAD * (RDSON, PFET + RINDUCTOR) + VOUT  
Buck Converter Operation (Continued)  
SHUTDOWN MODE  
ILOAD  
RDSON, PFET  
Load Current  
Drain to source resistance of PFET  
switch in the triode region  
Inductor resistance  
During shutdown the PFET switch, reference, control and  
bias circuitry of the converters are turned off. The NFET  
switch will be on in shutdown to discharge the output. When  
the converter is enabled, soft start is activated. It is recom-  
mended to disable the converter during the system power up  
and undervoltage conditions when the supply is less than  
2.8V.  
RINDUCTOR  
BUCK CONVERTER EFFICIENCY  
VIN (V)  
3.6  
VOUT (V)  
1.4  
IOUT (mA)  
100  
EFF(%)  
85  
SOFT START  
3.6  
1.4  
500  
89  
The buck converter has a soft-start circuit that limits in-rush  
current during start-up. During start-up the switch current  
limit is increased in steps. Soft start is activated only if EN  
goes from logic low to logic high after VIN reaches 2.8V. Soft  
start is implemented by increasing switch current limit in  
steps of 213 mA, 425 mA, 850 mA and 1700 mA (typ. Switch  
current limit). The start-up time thereby depends on the  
output capacitor and load current demanded at start-up.  
Typical start-up times with 10 µF output capacitor and 1000  
mA load current is 390 µs and with 1 mA load current its  
295 µs.  
3.6  
1.4  
1000  
84  
3.6  
1.4  
1500  
78  
VIN (V)  
3.6  
VOUT (V)  
3.3  
IOUT (mA)  
100  
EFF(%)  
92  
3.6  
3.3  
500  
96  
3.6  
3.3  
1000  
93  
3.6  
3.3  
1500  
90  
VIN (V)  
3.6  
VOUT (V)  
1.8  
IOUT (mA)  
100  
EFF(%)  
85  
LDO - LOW DROP OUT OPERATION  
The LP3971 can operate at 100% duty cycle (no switching;  
PMOS switch completely on) for low drop out support of the  
output voltage. In this way the output voltage will be con-  
trolled down to the lowest possible input voltage. When the  
device operates near 100% duty cycle, output voltage ripple  
is approximately 25 mV. The minimum input voltage needed  
to support the output voltage is  
3.6  
1.8  
500  
91  
3.6  
1.8  
1000  
87  
3.6  
1.8  
1500  
82  
I2C Compatible Interface  
I2C DATA VALIDITY  
The data on SDA line must be stable during the HIGH period of the clock signal (SCL). In other words, state of the data line can  
only be changed when CLK is LOW.  
20180714  
I2C START and STOP CONDITIONS  
generates START and STOP bits. The I2C bus is considered  
to be busy after START condition and free after STOP con-  
dition. During data transmission, I2C master can generate  
repeated START conditions. First START and repeated  
START conditions are equivalent, function-wise.  
START and STOP bits classify the beginning and the end of  
the I2C session. START condition is defined as SDA signal  
transitioning from HIGH to LOW while SCL line is HIGH.  
STOP condition is defined as the SDA transitioning from  
LOW to HIGH while SCL is HIGH. The I2C master always  
www.national.com  
16