Electrical Characteristics
(Note 5)
T
A
= T
J
Parameter
Large Signal Voltage Gain
Output Voltage Swing
Input Voltage Range
(Continued)
Conditions
V
S
=
±
15V, V
OUT
=
±
10V
R
L
≥
2k
V
S
=
±
15V
V
S
=
±
20V
V
S
=
±
15V
R
S
≤
50 kΩ
R
S
≤
50 kΩ
R
L
= 10 kΩ
R
L
= 2 kΩ
LM101A/LM201A
Min
25
Typ
Max Min
15
LM301A
Typ
Max
Units
V/mV
±
12
±
10
±
15
±
14
±
13
+15,
−13
±
12
±
10
±
12
70
70
±
14
±
13
+15,
−13
90
96
V
V
V
V
dB
dB
Common-Mode Rejection Ratio
Supply Voltage Rejection Ratio
80
80
96
96
Note 2:
Absolute Maximum Ratings indicate limits beyond which damage to the device may occur.Operating ratings indicate for which the device is functional, but
do no guarantee specific performance limits. Electrical Characteristics state DC and AC electrical specifications under particular test conditions which guarantee spe-
cific limits. This assumes that the device is within the Operating Ratings. Specifications are not guaranteed for parameters where no limit is given, however, the typical
value is a good indication of device performance.
Note 3:
For supply voltages less than
±
15V, the absolute maximum input voltage is equal to the supply voltage.
Note 4:
Continuous short circuit is allowed for case temperatures to 125˚C and ambient temperatures to 75˚C for LM101A/LM201A, and 70˚C and 55˚C respectively
for LM301A.
Note 5:
Unless otherwise specified, these specifications apply for C1 = 30 pF,
±
5V
≤
V
S
≤
±
20V and −55˚C
≤
T
A
≤
+125˚C (LM101A),
±
5V
≤
V
S
≤
±
20V and −25˚C
≤
T
A
≤
+85˚C (LM201A),
±
5V
≤
V
S
≤
±
15V and 0˚C
≤
T
A
≤
+70˚C (LM301A).
Note 6:
Refer to RETS101AX for LM101A military specifications and RETS101X for LM101 military specifications.
Note 7:
Human body model, 100 pF discharged through 1.5 kΩ.
Guaranteed Performance Characteristics
Input Voltage Range
Output Swing
LM101A/LM201A
Voltage Gain
DS007752-41
DS007752-42
DS007752-43
Guaranteed Performance Characteristics
Input Voltage Range
Output Swing
LM301A
Voltage Gain
DS007752-44
DS007752-45
DS007752-46
www.national.com
4