Typical Applications
(Note 9) (Continued)
Integrator with Bias Current Compensation
DS007752-25
*
Adjust for zero integrator drift. Current drift typically 0.1 nA/˚C over −55˚C to +125˚C temperature range.
Application Hints
(Note 9)
Protecting Against Gross
Fault Conditions
Compensating for Stray Input Capacitances
or Large Feedback Resistor
DS007752-26
*
Protects input
†
Protects output
‡
Protects output — not needed when R4 is used.
DS007752-27
Isolating Large Capacitive Loads
DS007752-28
Although the LM101A is designed for trouble free operation,
experience has indicated that it is wise to observe certain
precautions given below to protect the devices from abnor-
mal operating conditions. It might be pointed out that the ad-
9
vice given here is applicable to practically any IC op amp, al-
though the exact reason why may differ with different
devices.
www.national.com