Electrical Specifications (Continued)
6.3 ABSOLUTE MAXIMUM RATINGS
Table 6-3 lists absolute maximum ratings for the GXLV pro-
cessor. Stresses beyond the listed ratings may cause per-
manent damage to the device. Exposure to conditions beyond
these limits may (1) reduce device reliability and (2) result
in premature failure even when there is no immediately
apparent sign of failure. Prolonged exposure to conditions
at or near the absolute maximum ratings may also result
in reduced useful life and reliability. These are stress rat-
ings only and do not imply that operation under any condi-
tions other than those listed under Table 6-4 on page 189
is possible.
Table 6-3. Absolute Maximum Ratings
Symbol
Parameter
Min
Max
Units
Comments
TCASE
Operating Case Temperature
Storage Temperature
Core Supply Voltage
2.2V (Nominal)
–65
–65
110
150
°C
°C
Power Applied
No Bias
TSTORAGE
VCC2
2.9
3.2
3.2
6.0
10
V
V
2.5V (Nominal)
2.9V (Nominal)
V
VMAX
IIK
Voltage On Any Pin
Input Clamp Current
Output Clamp Current
–0.5
–0.5
V
mA
mA
Power Applied
Power Applied
IOK
25
www.national.com
188
Revision 1.1