Absolute Maximum Ratings (Note 2)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Recommended Operating
Conditions
Case Temperature (TC)
Military
−55˚C to +125˚C
−5.7V to −4.2V
Storage Temperature (TSTG
)
−65˚C to +150˚C
Supply Voltage (VEE
)
Maximum Junction Temperature (TJ)
Ceramic
+175˚C
−7.0V to +0.5V
VEE to +0.5V
−50 mA
Note 2: Absolute maximum ratings are those values beyond which the de-
vice may be damaged or have its useful life impaired. Functional operation
under these conditions is not implied.
VEE Pin Potential to Ground Pin
Input Voltage (DC)
Note 3: ESD testing conforms to MIL-STD-883, Method 3015.
Output Current (DC Output HIGH)
ESD (Note 3)
≥2000V
Military Version
DC Electrical Characteristics
=
=
=
=
VEE −4.2V to −5.7V, VCC VCCA GND, TC −55˚C to +125˚C
Symbol
Parameter
Min
Max Units
TC
Conditions
Notes
=
VOH
Output HIGH Voltage
−1025 −870
mV
0˚C to
VIN VIH (Max)
Loading with
1, 2, 3
or VIL (Min)
50Ω to −2.0V
+125˚C
−55˚C
−1085 −870
−1830 −1620
mV
mV
VOL
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
0˚C to
+125˚C
−55˚C
−1830 −1555
−1035
mV
mV
=
VOHC
0˚C to
VIN VIH (Max)
Loading with
1, 2, 3
or VIL (Min)
50Ω to −2.0V
+125˚C
−55˚C
−1085
−1610
mV
mV
VOLC
0˚C to
+125˚C
−55˚C
−1555
mV
mV
VIH
VIL
IIL
Input HIGH Voltage
Input LOW Voltage
Input LOW Current
Input HIGH Current
−1165 −870
−55˚C to
+125˚C
−55˚C to
+125˚C
−55˚C to
+125˚C
0˚C to
Guaranteed HIGH Signal for All Inputs
Guaranteed LOW Signal for All Inputs
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3
−1830 −1475
mV
µA
µA
µA
mA
=
VEE −4.2V
0.50
240
340
=
VIN VIL (Min)
=
IIH
VEE −5.7V
1, 2, 3
=
VIN VIH (Max)
+125˚C
−55˚C
IEE
Power Supply Current
−55˚C to
+125˚C
Inputs Open
=
−100
−105
−35
−35
VEE −4.2V to −4.8V
1, 2, 3
=
VEE −4.2V to −5.7V
Note 4: F100K 300 Series cold temperature testing is performed by temperature soaking (to guarantee junction temperature equals −55˚C), then testing immediately
without allowing for the junction temperature to stabilize due to heat dissipation after power-up. This provides “cold start” specs which can be considered a worst case
condition at cold temperatures.
Note 5: Screen tested 100% on each device at −55˚C, +25˚C, and +125˚C, Subgroups 1, 2, 3, 7, and 8.
Note 6: Sample tested (Method 5005, Table I) on each manufactured lot at −55˚C, +25˚C, and +125˚C, Subgroups A1, 2, 3, 7, and 8.
Note 7: Guaranteed by applying specified input condition and testing V /V
.
OH OL
Military Version
AC Electrical Characteristics
=
=
=
VEE −4.2V to −5.7V, VCC VCCA GND
=
=
=
Symbol
Parameter
TC −55˚C
TC +25˚C
TC +125˚C Units
Conditions
Notes
Min
Max
Min
Max
Min
Max
tPLH
tPHL
Propagation Delay
Dn to Output
0.50
2.70
0.50
2.30
0.50
2.80
ns
(Notes 8, 9,
10, 12)
Figures 1, 2, 3
3
www.national.com