Military Version
ECL-to-TTL AC Electrical Characteristics
V
EE
= −4.2V to −5.7V, V
TTL
= +4.5V to +5.5V, V
CC
= V
CCA
= GND, C
L
= 50 pF
Symbol
t
PLH
t
PHL
t
PLH
t
PHL
t
PZH
t
PZL
t
PHZ
t
PLZ
t
PHZ
t
PLZ
t
set
t
hold
t
pw
(H)
OE to T
n
(Enable Time)
OE to T
n
(Disable Time)
DIR to T
n
(Disable Time)
E
n
to LE
E
n
to LE
Pulse Width LE
3.2
3.6
3.2
3.0
2.6
2.7
2.5
3.0
2.5
8.0
8.0
8.5
8.0
7.0
7.0
3.7
4.0
3.3
3.4
2.6
3.1
2.0
2.5
2.0
8.0
8.5
8.0
7.5
7.0
7.0
4.0
4.3
3.5
4.1
2.9
4.0
2.5
3.0
5.0
9.2
9.6
8.4
10.0
8.0
10.0
ns
ns
ns
ns
ns
ns
Parameter
E
n
to T
n
(Transparent)
LE to T
n
3.1
7.0
3.1
6.5
3.3
7.5
ns
T
C
= −55˚C
Min
2.1
Max
6.0
T
C
= 25˚C
Min
2.0
Max
5.6
T
C
= +125˚C
Min
2.2
Max
6.3
ns
Units
Conditions
Notes
(Notes 12, 13,
14)
Figures 1, 2
Figures 3, 4
Figures 3, 4
Figures 3, 5
Figures 3, 6
Figures 3, 4
Figures 3, 4
Figures 3, 4
(Notes 12, 13,
14)
(Note 15)
(Note 15)
Note 12:
F100K 300 Series cold temperature testing is performed by temperature soaking (to guarantee junction temperature equals −55˚C), then testing immedi-
ately after power-up. This provides “cold start” specs which can be considered a worst case condition at cold temperatures.
Note 13:
Screen tested 100% on each device at +25˚C, temperature only, Subgroup A9.
Note 14:
Sample tested (Method 5005, Table I) on each mfg. lot at +25˚C, Subgroup A9, and at +125˚C and −55˚C temperatures, Subgroups A10 and A11.
Note 15:
Not tested at +25˚C, +125˚C and −55˚C temperature (design characterization data).
www.national.com
6