Absolute Maximum Ratings (Note 2)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Operating Range (Note 2)
ESD (Note 3)
−5.7V to −4.2V
≥2000V
Recommended Operating
Conditions
Case Temperature (TC)
Military
Above which the useful life may be impaired
Storage Temperature
−65˚C to +150˚C
Maximum Junction Temperature (TJ)
Ceramic
−55˚C to +125˚C
−5.7V to −4.2V
+175˚C
–55˚C to +125˚C
−7.0V to +0.5V
VCC to +0.5V
−50 mA
Supply Voltage (VEE
)
Case Temperature under Bias (TC)
VEE Pin Potential to Ground Pin
Input Voltage (DC)
Note 2: Absolute maximum ratings are those values beyond which the de-
vice may be damaged or have its useful life impaired. Functional operation
under these conditions is not implied.
Note 3: ESD testing conforms to MIL-STD-883, Method 3015.
Output Current (DC Output HIGH)
Military Version
DC Electrical Characteristics
=
=
=
VEE −4.2V to −5.7V, VCC VCCA GND (Note 6)
Symbol
Parameter
Output HIGH
Voltage
Min
Typ
Max
Units
TC
Conditions
Notes
VOH
−1025
−870
mV
0˚C to
+125˚C
−55˚C
0˚C to
+125˚C
−55˚C
0˚C to
+125˚C
−55˚C
−1085
−1830
−870
mV
mV
=
VIN VIH(Max)
Loading with
(Notes
4, 5, 6)
or VIL(Min)
50Ω to −2.0V
VOL
Output LOW
Voltage
−1620
−1830
−1035
−1555
mV
mV
VOHC
Output HIGH
Voltage
−1085
mV
mV
(Notes
4, 5, 6)
=
VIN VIH(Min)
Loading with
or VIL(Max)
50Ω to −2.0V
VOLC
Output LOW
Voltage
−1610
−1555
0˚C to
+125˚C
−55˚C
mV
DC Electrical Characteristics
=
=
=
VEE −4.2V to −5.7V, VCC VCCA GND (Note 6)
Symbol
Parameter
Input Voltage
Differential
Min
Typ
Max
Units
TC
Conditions
Notes
VDIFF
150
mV
−55˚C to Required for Full
(Notes 4, 5,
6)
+125˚C
Output Swing
VCM
VIH
VIL
IIH
Common Mode
Voltage
VCC − 2.0
−1165
VCC − 0.5
−870
V
−55˚C to
(Notes 4, 5,
6)
+125˚C
Single-Ended
Input High Voltage
Single-Ended
Input Low Voltage
Input HIGH Current
CLKIN, CLKIN
TCLK
mV
mV
µA
−55˚C to Guaranteed HIGH Signal
(Notes 4, 5,
6, 7)
+125˚C
−55˚C to Guaranteed LOW Signal
+125˚C for All Inputs
for All Inputs
−1830
−1475
150
(Notes 4, 5,
6, 7)
=
−55˚C to VIN VIH(Max)
+125˚C
(Notes 4, 5,
6)
450
380
µA
µA
µA
CLKSEL
=
ICBO
Input Leakage
Current
−10
−80
−55˚C to VIN VEE
(Notes 4, 5,
6)
+125˚C
−55˚C to
+125˚C
IEE
Power Supply
Current, Normal
−25
mA
(Notes 4, 5,
6)
Note 4: F100K 300 Series cold temperature testing is performed by temperature soaking (to guarantee junction temperature equals −55˚C), then testing immediately
without allowing for the junction temperature to stabilize due to heat dissipation after power-up. This provides “cold start” specs which can be considered a worst case
condition at cold temperatures.
www.national.com
2