AC Electrical Characteristics
=
=
=
VEE −4.2V to −5.7V, VCC VCCA GND
=
=
=
TC
+125˚C
TC
TC
Symbol
Parameter
Units
Conditions
Notes
−55˚C
+25˚C
Min Max
Min Max
Min Max
tPLH
tPHL
tTLH
tTHL
Propagation Delay
Data to Output
0.40 2.30 0.60 2.20 0.60 2.70
0.20 1.40 0.20 1.40 0.20 1.40
ns
ns
(Notes 7, 8, 9)
(Note 10)
Figures 1, 2
Transition Time
20% to 80%, 80% to 20%
Note 7: F100K 300 Series cold temperature testing is performed by temperature soaking (to guarantee junction temperature equals −55˚C), then testing immediately
after power-up. This provides “cold start” specs which can be considered a worst case condition at cold temperatures.
Note 8: Screen tested 100% on each device at +25˚C temperature only, Subgroup A9.
Note 9: Sample tested (Method 5005, Table I) on each manufactured lot at +25˚C, Subgroup A9, and at +125˚C and −55˚C temperatures, Subgroups A10 and A11.
Note 10: Not tested at +25˚C, +125˚C and −55˚C temperature (design characterization data).
Test Circuit
DS100299-5
=
=
Note: V , V
+2V, V
−2.5V
CC CCA
EE
=
L1 and L2 equal length 50Ω impedance lines
=
R
T
50Ω terminator internal to scope
Decoupling 0.1 µF from GND to V and V
CC EE
All unused outputs are loaded with 50Ω to GND
=
C
L
Fixture and stray capacitance ≤ 3 pF
FIGURE 1. AC Test Circuit