Nexperia
74HC08-Q100; 74HCT08-Q100
Quad 2-input AND gate
8 Recommended operating conditions
Table 5. Recommended operating conditions
Voltages are referenced to GND (ground = 0 V)
Symbol Parameter
Conditions
74HC08-Q100
74HCT08-Q100
Unit
Min
Typ
Max
Min
Typ
Max
VCC
VI
supply voltage
input voltage
2.0
5.0
6.0
VCC
VCC
+125
625
139
83
4.5
5.0
5.5
VCC
VCC
V
V
V
0
0
-
0
0
-
VO
output voltage
ambient temperature
-
-
Tamb
Δt/ΔV
-40
-
-
-40
-
-
+125 °C
input transition rise and fall rate VCC = 2.0 V
-
1.67
-
-
1.67
-
-
139
-
ns/V
VCC = 4.5 V
VCC = 6.0 V
-
-
ns/V
ns/V
-
-
9 Static characteristics
Table 6. Static characteristics
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
25 °C
-40 °C to
+85 °C
-40 °C to
+125 °C
Unit
Min
Typ Max Min Max Min Max
74HC08-Q100
VIH
HIGH-level
input voltage
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
VI = VIH or VIL
1.5
1.2
2.4
3.2
0.8
2.1
2.8
-
-
1.5
-
-
1.5
-
-
V
V
V
V
V
V
3.15
3.15
3.15
4.2
-
4.2
-
4.2
-
VIL
LOW-level
input voltage
-
-
-
0.5
1.35
1.8
-
-
-
0.5
1.35
1.8
-
-
-
0.5
1.35
1.8
VOH
HIGH-level
output voltage
IO = -20 μA; VCC = 2.0 V
1.9
4.4
2.0
4.5
-
-
-
-
-
1.9
4.4
-
-
-
-
-
1.9
4.4
5.9
3.7
5.2
-
-
-
-
-
V
V
V
V
V
IO = -20 μA; VCC = 4.5 V
IO = -20 μA; VCC = 6.0 V
IO = -4.0 mA; VCC = 4.5 V
IO = -5.2 mA; VCC = 6.0 V
5.9
6.0
5.9
3.98
5.48
4.32
5.81
3.84
5.34
VOL
LOW-level
VI = VIH or VIL
output voltage
IO = 20 μA; VCC = 2.0 V
IO = 20 μA; VCC = 4.5 V
IO = 20 μA; VCC = 6.0 V
IO = 4.0 mA; VCC = 4.5 V
-
-
-
-
0
0
0.1
0.1
-
-
-
-
0.1
0.1
-
-
-
-
0.1
0.1
0.1
0.4
V
V
V
V
0
0.1
0.1
0.15
0.26
0.33
74HC_HCT08_Q100
All information provided in this document is subject to legal disclaimers.
© Nexperia B.V. 2017. All rights reserved.
Product data sheet
Rev. 2 — 13 June 2017
4 / 15