 浏览型号NHD-3.12-25664UMY3的Datasheet PDF文件第13页浏览型号NHD-3.12-25664UMY3的Datasheet PDF文件第14页浏览型号NHD-3.12-25664UMY3的Datasheet PDF文件第15页浏览型号NHD-3.12-25664UMY3的Datasheet PDF文件第16页浏览型号NHD-3.12-25664UMY3的Datasheet PDF文件第17页浏览型号NHD-3.12-25664UMY3的Datasheet PDF文件第18页浏览型号NHD-3.12-25664UMY3的Datasheet PDF文件第19页浏览型号NHD-3.12-25664UMY3的Datasheet PDF文件第20页  
17.Quality Information  
Test Item  
Content of Test  
Test Condition  
+90C , 240hrs  
Note  
2
High Temperature storage Test the endurance of the display at high  
storage temperature.  
Low Temperature storage Test the endurance of the display at low  
storage temperature.  
40C , 240hrs  
+85C 240hrs  
1,2  
2
High Temperature  
Operation  
Test the endurance of the display by  
applying electric stress (voltage & current)  
at high temperature.  
Low Temperature  
Operation  
Test the endurance of the display by  
applying electric stress (voltage & current)  
at low temperature.  
Test the endurance of the display by  
applying electric stress (voltage & current)  
at high temperature with high humidity.  
Test the endurance of the display by  
applying electric stress (voltage & current)  
during a cycle of low and high  
40C , 240hrs  
1,2  
1,2  
High Temperature /  
Humidity Operation  
+60C , 90% RH , 240hrs  
Thermal Shock resistance  
40C,30min > 25C,5min >  
85C,30min = 1 cycle  
100 cycles  
temperatures.  
Vibration test  
Test the endurance of the display by  
applying vibration to simulate  
transportation and use.  
1022Hz , 15mm amplitude.  
22500Hz, 1.5G  
30min in each of 3 directions  
X,Y,Z  
115mbar, 40hrs  
3
3
Atmospheric Pressure test Test the endurance of the display by  
applying atmospheric pressure to simulate  
transportation by air.  
Static electricity test  
Test the endurance of the display by  
applying electric static discharge.  
VS=800V, RS=1.5kΩ, CS=100pF  
One time  
Note 1: No condensation to be observed.  
Note 2: Conducted after 2 hours of storage at 25C, 0%RH.  
Note 3: Test performed on product itself, not inside a container.  
Evaluation Criteria:  
1: Display is fully functional during operational tests and after all tests, at room temperature.  
2: No observable defects.  
3: Luminance >50% of initial value.  
4: Current consumption within 50% of initial value  