CHAPTER 15 STANDBY FUNCTION  
15.2 Standby Function Operation  
15.2.1 HALT mode  
(1) HALT mode  
The HALT mode is set by executing the HALT instruction.  
The operation status in the HALT mode is shown in the following table.  
Table 15-1. HALT Mode Operating Status  
Item  
HALT Mode Operation Status While The Main  
System Clock Is Running  
HALT Mode Operation Status While The  
Subsystem Clock Is Running  
While the subsystem  
clock is running  
While the subsystem  
clock is not running  
While the main system  
clock is running  
While the main system  
clock is not running  
Main system clock  
CPU  
Oscillation enabled  
Operation stopped  
Oscillation stopped  
Port (output latch)  
16-bit timer  
Remains in the state existing before the selection of HALT mode.  
Operation enabled  
Operation stopped  
Operation enabledNote 1  
Operation enabledNote 2  
Operation enabledNote 4  
8-bit timer  
TM50  
TM60  
Operation enabled  
Watch timer  
Operation enabled  
Operation enabled  
Operation enabled  
Operation stopped  
Operation enabled  
Operation enabledNote 6  
Operation enabledNote 3  
Operation enabled  
Operation stopped  
Watchdog timer  
Serial interface  
A/D converter  
Operation stoppedNote 5  
Operation enabledNote 4  
LCD controller/driver  
External interrupt  
Operation enabledNote 3  
Operation enabled  
Notes 1. Operation is enabled only when input signal from timer 60 (timer 60 operation is enabled) is selected  
as the count clock.  
2. Operation is enabled when TMI60 is selected as the count clock.  
3. Operation is enabled while the main system clock is selected.  
4. Operation is enabled while the subsystem clock is selected.  
5. Operation is enabled only when external clock is selected.  
6. Maskable interrupt that is not masked  
User’s Manual U15075EJ1V0UM00  
281  