■ Specifications and Test Methods
No Item
15 Durability
Specification
Test Method(Ref. Standard:JIS C 5101, IEC60384)
Appearance
Capacitance Change
DC Resistance
I.R.
No defects or abnormalities.
Within +/-12.5%
50mΩ below
Mounting method
Pre-treatment
Solder the capacitor on the test substrate
Heat treatment:Perform a heat treatment at 150+0/-10°C for 1hour and then let sit for 48+/-4hours
at room temperature, then measure.
Maximum Operating Temperature +/-3℃
1000+/-12h
More than 105MΩ
Test Temperature
Test Time
Test Voltage
200% of the rated voltage
Charge/discharge current 50mA max.
Post-treatment
Non treatment:Let sit for 48+/-4hours at room temperature, then measure. If it’s doubt,
perform a heat treatment at 150+0/-10°C for 1hour and then let sit for 48+/-4hours
at room temperature, then measure.
NFM18PC474R0J3-0-770
4