■ Specifications and Test Methods
No Item
Specification
Test Method(Ref. Standard:AEC-Q200)
-
-
1 Pre-and Post-Stress
Electrical Test
Appearance
Capacitance Change
Q or D.F.
No defects or abnormalities.
Within +/-2.5%
Q≧350
Mounting method
Test Temperature
Test Time
Solder the capacitor on the test substrate
Maximum Operating Temperature +/-3℃
1000+/-12h
2 High Temperature
Exposure (Storage)
I.R.(Room Temp.)
More than 10000MΩ
Post-treatment
Non treatment:Let sit for 24+/-2hours at room temperature, then measure.
Appearance
Capacitance Change
Q or D.F.
No defects or abnormalities.
Within +/-2.5%
Q≧1000
Mounting method
Temperature Cycling
Solder the capacitor on the test substrate
3 Temperature Cycling
I.R.(Room Temp.)
More than 10000MΩ
Post-treatment
Per EIA-469
Non treatment:Let sit for 24+/-2hours at room temperature, then measure.
Appearance
No defects or abnormalities.
4 Destructive Physical
Analysis
Appearance
Capacitance Change
Q or D.F.
No defects or abnormalities.
Within +/-3%
Q≧200
Mounting method
Test Temperature
Test Humidity
Test Time
Solder the capacitor on the test substrate
85+/-3℃
80%RH to 85%RH
1000+/-12h
5 Biased Humidity
I.R.(Room Temp.)
More than 1000MΩ
Test Voltage
The rated voltage and 1.3+0.2/-0Vdc (add 6.8kΩ resister)
Charge/discharge current 50mA max.
Post-treatment
Non treatment:Let sit for 24+/-2hours at room temperature, then measure.
Appearance
Capacitance Change
Q or D.F.
No defects or abnormalities.
Within +/-3%
Q≧350
Mounting method
Test Temperature
Test Time
Solder the capacitor on the test substrate
Maximum Operating Temperature +/-3℃
1000+/-12h
6 Operational Life
I.R.(Room Temp.)
More than 1000MΩ
Test Voltage
100% of the rated voltage
Charge/discharge current 50mA max.
Post-treatment
Non treatment:Let sit for 24+/-2hours at room temperature, then measure.
No defects or abnormalities.
Shown in Dimension.
Visual inspection
7 Appearance
Using Measuring instrument of dimension.
Per MIL-STD-202 Method 215
8 Dimension
Appearance
Capacitance
Q or D.F.
No defects or abnormalities.
9 Resistance to Solvents
Within the specified initial value.
Within the specified initial value.
More than 10000MΩ
I.R.(Room Temp.)
GRT0335C2A820FA02-01A
2